Onwa KF-667 manual Selecting Picture Advance Speed, Display Range Selection, Basic range selection

Page 16

2.6 Selecting Picture Advance Speed

The picture advance speed determines how quickly the vertical scan lines run across the screen. When selecting a picture advance speed, keep in mind that a fast advance speed will expand the size of the fish school horizontally on the screen and a slow advance speed will contract it.

1.Press the [BRILL] and [AUTO] keys together. The display should look something like the one below. The fraction shown on the display denotes number of scan lines produced per transmission. For example, 1/8 means one scan line is produced every eight transmissions.

0 freezes the display and it is convenient for observing an echo.

ADVANCE:1

(1/8)

2.Continue pressing the [BRILL] and [AUTO] keys together to select desired speed.

2.7 Display Range Selection

The basic range and range shifting functions used together give you the means to select the depth you can see on the screen. The basic range can be thought of as providing a window into the water column and range shifting as moving the Window to the desired depth.

Shift

Display

2.7.1 Basic range selection

The basic range may be selected with the [RANGE] switch from the eight ranges shown in the table below.

Table 1-1 Basic ranges(default settings)

Range No

1

2

3

4

5

6

7

8

 

Meters

5

10

20

40

80

150

200

300

 

Feet

15

30

60

120

200

400

600

1000

 

Fathoms

3

5

10

20

40

80

100

150

 

Passi/Braza(P/B)

3

5

10

30

50

100

150

200

 

2-5

Image 16
Contents Model KF-667 Safety Instructions Table of Contents Features IntroductionPage Principle of Operation System Configuration Display UnitTransducer PowerTD/Temp CONTROLS, Indications Control FunctionBrill Indications VoltageTurning the Power On/Off Adjusting BrillianceDisplay Mode Selection, Description Display mode selection200K, 50K high frequency, low frequency mode Display mode descriptionDual frequency mode Zoom mode high or low frequency Marker ZoomAdjusting Gain Automatic OperationHow it works Enabling automatic operationDisplay Range Selection Selecting Picture Advance SpeedBasic range selection Erasing Weak Echoes Range shiftingMeasuring Depth to a Fish School Scope DisplayMenu Operation Menu selectionMain menu description System MenuSystem menu description Menu item Description System MenuSuppressing Interference Suppressing Low Level NoiseAlarm description AlarmsSelecting Background and Echo Colors Activating/deactivating an alarm Silencing the buzzerWhite Marker Interpreting the Display Zero LineFish School Echoes Bottom EchoSurface Noise/Aeration MAINTENANCE,TROUBLESHOOTING MaintenanceReplacement of fuse General checkingCleaning Maintenance of the transducerBasic Troubleshooting Basic troubleshootingWater Temperature Sensor option Check Transducer CheckMenu Tree MENU1Specifications on Color Video Sounder KF-667Power Supply Index