Onwa KF-667 manual Activating/deactivating an alarm, Silencing the buzzer

Page 24

2.15.2 Activating/deactivating an alarm

1.Prees the [ALARM] key to display the alarm menu.

BOTTOM

ALARM ZONE: RANGE:

FISH ALARM ZONE:

RANGE:

TEMP ALARM ZONE:

RANGE

 

 

 

ON

 

 

---

5

 

0

 

 

 

5

 

 

 

ON

 

OFF

 

 

 

---

5

 

0

 

 

 

5

OFF IN OUT 32 --- 37

5

/ TO SELECT ITEM.

-/+ TO SET CONDITION.

2.Press [] or [] to select an alarm

.

3.Press [+]to select ON, IN or OUT.(For the water temperature alarm, select IN to get the alarm when the water temperature is within the alarm zone range, or OUT to get the alarm when the water temperature is higher than the alarm zone range.)

4.Press [] to select ALARM ZONE.

5.Adjust width of alarm zone with [+] or [-].

Alarm

zone

Alarm zone marker

(Fish, bottom alarms only)

Alarm icon (Appear when alarm is violated.)

6.Press [] to select RANGE.

7.Use [+] to [-] to set display range for the alarm.

To deactivate an alarm, select OFF at step 3 in the above procedure.

2.15.3 Silencing the buzzer

When an alarm is violated, the buzzer sounds and the alarm icon and name of alarm violated (see illustration above) appear on the display. You can temporarily silence the buzzer by Pressing the [ALARM] key. However, the buzzer will sound the next time the alarm setting is violated.

2-13

Image 24
Contents Model KF-667 Safety Instructions Table of Contents Features IntroductionPage Principle of Operation System Configuration Display UnitPower TransducerTD/Temp CONTROLS, Indications Control FunctionBrill Indications VoltageTurning the Power On/Off Adjusting BrillianceDisplay Mode Selection, Description Display mode selectionDisplay mode description 200K, 50K high frequency, low frequency modeDual frequency mode Zoom mode high or low frequency Marker ZoomAdjusting Gain Automatic OperationHow it works Enabling automatic operationSelecting Picture Advance Speed Display Range SelectionBasic range selection Erasing Weak Echoes Range shiftingMeasuring Depth to a Fish School Scope DisplayMenu Operation Menu selectionMain menu description System Menu System menu description Menu item Description System MenuSuppressing Interference Suppressing Low Level NoiseAlarms Alarm descriptionSelecting Background and Echo Colors Activating/deactivating an alarm Silencing the buzzerWhite Marker Interpreting the Display Zero LineFish School Echoes Bottom EchoSurface Noise/Aeration MAINTENANCE,TROUBLESHOOTING MaintenanceReplacement of fuse General checkingCleaning Maintenance of the transducerBasic Troubleshooting Basic troubleshootingWater Temperature Sensor option Check Transducer CheckMenu Tree MENU1Specifications on Color Video Sounder KF-667Power Supply Index