Onwa KF-667 manual Maintenance,Troubleshooting, General checking, Replacement of fuse

Page 28

4.MAINTENANCE,TROUBLESHOOTING

WARNING

ELECTRICAL SHOCK HAZARD

Do not open the equipment.

Only qualified personnel should work inside the equipment.

4.1 Maintenance

Regular maintenance is important for good performance. Following the recommended maintenance procedures will help keep your set in good working condition.

4.1.1 General checking

Important points to be checked from time to time are tabulated below.

Maintenance check points

Check point

Action

Transducer cable

If conductors are exposed, replace cable.

Power cable plug/transducer cable plug

If loosened, tighten.

Display unit ground

.

 

If corroded, clean

Ship’s mains voltage

If out of ratings, correct problem.

4.1.2 Replacement of fuse

The fuse on the power cable protects the equipment against overvoltage/reverse polarity of the ship’s mains or internal fault of the equipment. If the fuse blows, find the cause before replacing the fuse. If the fuse blows again after replacement, call for service. A fuse rated for more than 3A should not be used since it would damage the equipment and void the warranty.

CAUTION

Use the proper fuse.

Use of a wrong fuse can cause fire or equipment damage.

4-1

Image 28
Contents Model KF-667 Safety Instructions Table of Contents Features IntroductionPage Principle of Operation System Configuration Display UnitTransducer PowerTD/Temp CONTROLS, Indications Control FunctionBrill Indications VoltageTurning the Power On/Off Adjusting BrillianceDisplay Mode Selection, Description Display mode selection200K, 50K high frequency, low frequency mode Display mode descriptionDual frequency mode Zoom mode high or low frequency Marker ZoomAdjusting Gain Automatic OperationHow it works Enabling automatic operationDisplay Range Selection Selecting Picture Advance SpeedBasic range selection Erasing Weak Echoes Range shiftingMeasuring Depth to a Fish School Scope DisplayMenu Operation Menu selectionMain menu description System MenuSystem menu description Menu item Description System MenuSuppressing Interference Suppressing Low Level NoiseAlarm description AlarmsSelecting Background and Echo Colors Activating/deactivating an alarm Silencing the buzzer White Marker Interpreting the Display Zero LineFish School Echoes Bottom EchoSurface Noise/Aeration MAINTENANCE,TROUBLESHOOTING MaintenanceReplacement of fuse General checkingCleaning Maintenance of the transducerBasic Troubleshooting Basic troubleshootingWater Temperature Sensor option Check Transducer CheckMenu Tree MENU1Specifications on Color Video Sounder KF-667Power Supply Index