Troubleshooting

to 60ft or whatever depth you expect the fish to appear at. This will maximize the screen resolution to show small ob- jects larger on the screen. It is unlikely you will see average- sized fish display as arches in a 100ft deep water column.

4.The boat must be moving at a slow trolling speed to see fish arches. If the boat is motionless, fish stay in the cone and show as horizontal lines on screen. This is especially applicable to ice fishing.

Noise

1.A major cause of sonar problems is electrical noise. This usually appears on the sonar’s display as random patterns of dots or lines. In severe cases, it can completely cover the screen with black dots, or cause the unit to operate errati- cally, or not at all.

2.To eliminate or minimize the effects of electrical noise, try to determine the cause. With the boat at rest in

the water, turn all electrical equipment on the boat off including the engine. Turn on your sonar unit. Sensitivity should be set at 70-75 percent. There should be a steady bottom signal on the display. Now turn on each piece of electrical equipment on the boat and view the effect on the sonar’s display.

3.If you find noise interference is from an electrical instru- ment, trolling motor, pump, or radio, you can usually reroute the sonar unit’s power cable and transducer cable away from the wiring causing the interference. VHF radio antenna cables radiate noise when transmitting, so be sure to keep the sonar’s wires away from it. You may need to route the sonar unit’s power cable directly to the battery to isolate it from other wiring on the boat.

4.If no noise displays on the sonar unit from electrical equip- ment, then make sure everything except the sonar unit is turned off, then start the engine. Increase the RPM with the gearshift in neutral. If noise appears on the display, the problem could be one of three things; spark plugs, alterna- tor, or tachometer wiring. Try using resistor spark plugs, al- ternator filters, or routing the sonar unit’s power cable away from engine wiring to help eliminate noise problems. Make sure to use the in-line fuse supplied with the unit when wir- ing the power cable to the battery.

82

Image 84
Contents HDS-5x Copyright 2011 Navico All Rights Reserved Table of contents Contents Introduction About this manual Manual ConventionsLowrance HDS-5x Sonar Getting Started Language MenusClosing Menus To select a languageSelecting a Fishing Mode To select a fishing modeEntering Letters in Text Boxes To enter data in a text boxRestore Defaults To Restore DefaultsPages Pages ScreenSelecting Pages To access Edit Overlay menu Edit ModeData Overlay Data Overlay menuMove or Placing a Gauge To move/place a gaugeSelect Data TypeSize LimitsConfiguration menu Add SourceTo add a source To remove add source dataSonar On the Sonar Page you canRadar Page optional InfoOn the Radar Page you can On the Info Page you canInfo menu DashboardsEdit To edit gauge display Edit Info menuTo select info To Configure Limits To add sourceTo remove a source Change Layout To change layoutAdd Dashboard To add a dashboardSettings To access UtilitiesUtilities UtilitiesDisplaying Combo Pages Selecting an Active PanelTo display a combo Adjust Panel Sizes Displaying Multiple PanelsTo display multiple panels Left the Info page on the rightTo adjust panel sizes To access the Sonar Sonar OperationSonar Menu Auto SensitivitySensitivity Colorline RangeFrequency SplitAdjust To Adjust Sensitivity and ColorlineStop Sonar To set Upper and Lower Limits Sonar OptionsCustom Upper and Lower Limits Ping SpeedPalette To select a Split optionTo select a Palette Temperature Graph Depth LineAmplitude Scope Zoom BarsMeasure Distance Fish IDTo select a Fish ID option To Measure distanceTo share/receive sonar data To access the Radar Radar Operation optionalAdjust menu To access the Adjust menuRadar menu Radar StateAuto Gain Low, Medium and HighTo select Auto Gain Sea Clutter Acquire TargetsPosition To change the PPI positionSymbology Look AheadAdjust To adjust an EBL/VRMEBL/VRM menu To select an EBL/VRMGuard Zones Data BoxUsing the Adjust menu To choose alarm trigger vessels entering or exiting zonesTo turn on a Guard Zone To change the shape of Guard ZonesSettings Menu To access the System menuSystem LanguageTo change Key Beep settings To change Text SizeKey Beeps Time optionalRestore Defaults Screen CaptureTo take a screen capture AdvancedTo access Advanced Settings To adjust cursor settingsPages AboutSonar Settings Network SonarNoise Rejection Surface ClarityManual Mode To adjust Surface ClarityScroll Speed Fishing Modes Installation Menu Reset Fishing ModeKeel Offset Water Speed Calibration To set Keel OffsetTo calibrate Water Speed Temperature Calibration Temperature AveragingWater Speed Averaging To select a Water Averaging intervalTo select a Temperature Averaging interval Transducer TypeTo select a Transducer Type Radar Settings Menu optional Target ExpansionTarget Trails PaletteNorth Indicator OrientationThreshold To change Map OrientationRange Rings Range MarkersCompass BearingsMarpa To set T/M or RTo adjust CPA and Tcpa settings Canceling Marpa targetsSelecting Marpa targets To cancel individual targets To cancel all targetsMarpa Settings To select history lengthInstallation Target AlarmsTo set Marpa target alarm To access Radar Installation menuInstallation Adjustment Menu Bearing alignmentTo select Heading up orientation To Adjust Bearing Alignment To Adjust Range OffsetRange offset Fast scan mode BR24 Radar only To Adjust Antenna HeightAntenna Height TuneReset Radar to Factory Defaults Manually adjusting Sidelobe suppressionSidelobe suppression BR24 only Fuel RefuelTo input fuel added To set tank to full To calibrate enginesVessel Setup Fuel UsedEngine/Tank Configuration To select engine-tank configurationTo input tank size CalibrateAlarms To enable/disable an AlarmSiren Enabled UnitsAuto Configure To auto configure a networkNetwork Data SourcesData Source menu RenameTo Rename a data source NewReset Global and Reset Local To reset global or local sourcesTo select a scope Device ListConfiguring Devices To configure a device name or device tank sizeTo configure device location To access calibration instructionsInstance Calibrating devicesDiagnostics Nmea 2000 receive/send waypointTo view waypoints Serial PortsTo configure serial ports To access Nmea 0183 Output screenNmea 0183 Output To adjust CPA or Tcpa settings Demo ModeTo choose a Demo Mode SimulatorSpecifications HDS-5x GeneralCleaning the screen Unit Care Troubleshooting Unit won’t turn on Unit freezes, locks up, or operates erratically Weak bottom echo, erratic readings or no fish returnsTroubleshooting No fish arches when Fish I.D. is turned off Noise Update the Software Reset the UnitRadar won’t Start Up Troubleshooting Index IndexMarpa Index