1.43 Background Color

The secondary function of the BRILL control (BKGND COLOR) is to select the color of the background, characters, menu, markers and indications, from the five color combinations shown in the table below. Each press of the control selects one of the five color combina- tions.

Table 1-4 Available color combinations

Arrangement

1

2

3

4

5

 

 

 

 

 

 

Radar Display

BLK

BLU

BLU

BLU

BLK

Area

 

 

 

 

 

 

 

 

 

 

 

Outside Radar

BLK

BLK

BLK

BLU

BLK

Display Area

 

 

 

 

 

 

 

 

 

 

 

Characters

GRN

GRN

GRN

WHT

RED

 

 

 

 

 

 

Menu

YEL

YEL

YEL

YEL

RED

 

 

 

 

 

 

Menu Highlight

YEL

YEL

YEL

YEL

RED

 

 

 

 

 

 

EBL/VRM

L-BLU

GRN

GRN

GRN

L-BLU

 

 

 

 

 

 

Range Rings

GRN

WHT

WHT

WHT

GRN

 

 

 

 

 

 

Cursor

WHT

GRN

GRN

GRN

WHT

 

 

 

 

 

 

Heading Line

GRN

WHT

WHT

WHT

GRN

 

 

 

 

 

 

Target Alarm

WHT

L-BLU

L-BLU

L-BLU

WHT

Zone

 

 

 

 

 

 

 

 

 

 

 

North Marker

WHT

L-BLU

L-BLU

L-BLU

WHT

 

 

 

 

 

 

Stern Marker

WHT

L-BLU

L-BLU

L-BLU

WHT

 

 

 

 

 

 

BLK, Black; BLU, Blue; L-BLU, Light-blue; WHT, White; GRN, Green, YEL, Yellow

1.44 Selecting Range Scales

Range scales to use may be selected as fol- lows:

1.Press the [MENU] key.

2.Press the [0] key four times to display the OTHER sub menu.

OTHER

1.

2.TEST

3.DEGAUSS

4.TIME ALARM

5.RANGE

6.INSTALL

Figure 1-53 OTHER sub menu

3. Press the [5] key twice to select RANGE.

 

 

RANGE

 

 

 

 

 

 

 

 

1.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2.

RANGE

 

1/8

 

 

1/4

 

 

1/2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3/4

 

 

1

1.5

 

2

3

 

 

 

4

6

8

12

16

 

 

 

 

24

 

 

32

48

 

72

96

120

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 1-54 RANGE menu

4.Press the [2] key to place the underline under the range scale to select/deselect and then press the [ENTER/SELECT] key. Active ranges are highlighted. Repeat to select/deselect other ranges.

5.Press the [MENU] key.

1.45Selecting Bearing Scale Format

The bearing scale may be displayed in de- grees or compass points or degrees as fol- lows:

1.Press the [MENU] key.

2.Press the [0] key twice to display the OTHER menu.

3.Press the [6] key twice to display the MARK/LINE menu.

 

MARK/LINE

 

1.

 

 

 

 

 

 

 

 

 

 

2.

INDEX LINES

2

 

 

6

 

 

 

 

3.

STERN MARK

OFF

 

ON

 

 

 

 

4.

SHIP’S MARK

OFF

 

ON

 

 

 

 

 

5.

BEARING SCALE

360

 

COMPASS

 

 

 

 

 

 

Figure 1-55 MARK/LINE menu

4.Press the [5] key to select 360 (degrees) or COMPASS.

5.Press the [ENTER/SELECT] key to reg- ister your selection and the [MENU] key to close the menu.

1-33

Image 47
Contents Marine Radar First Edition NOV Keep heater away from equipment Do not operate the equipment with wet handsUse the proper fuse Do not open the equipmentDo not disassemble or modify the equipment Table of Contents Declaration of Conformity FR-1760DS SP-1Word to the Owner of This Furuno Radar FeaturesIntroduction FR-1760DS System ConfigurationAntenna Unit Display Unit FR-1710/1725Viii Menu TreePlot Menu Mark Disp OFF Erase VEC REF REL True VEC Time Curs RNG INT REJ OFF Stretch Enhance Contrast Auto Xii Transmitter on Turning on the PowerOperational Overview Control description Control DescriptionControl Panel Backlighting Tuning the ReceiverCRT Brilliance Initializing the Compass Readout Degaussing the ScreenOn-screen legends and markers On-screen Legends and MarkersPresentation Modes Selecting presentation modeCourse-up Mode Screen shows Selecting the Range ScaleManual speed input Entering Own Ship’s SpeedAutomatic speed input 10 Echo stretch Pulselength, Echo StretchS1P Suppressing Sea Clutter Adjusting the SensitivityManual adjustment by the A/C SEA control Automatic adjustment by the A/C Auto controlInterference Rejector Suppressing Precipitation ClutterMeasuring range by the variable range marker VRM Measuring the RangeMeasuring Bearing Measuring range by the fixed range ringsMeasuring Range and Bearing Between Two Targets Collision Assessment by the Offset EBL18 Measuring range and bearing Between two targets Setting a Target Alarm ZoneOff-centering shift Acknowledging alarmDeactivating target alarm zone Inward and outward alarms23 Echo SIG menu Echo AveragingPlotting a target Electronic Plotting Aid EPAReading the target data True or relative vector, vector timeTarget data Terminating target plottingCPA/TCPA Alarm Setting CPA/TCPA alarm rangesSilencing CPA/TCPA audible alarm Lost target alarmTrue or relative trails Target Trails Echo TrailsPast plot points Displaying, erasing target trails Trail gradationSelecting trail time Restoring trailsTrail afterglow Resetting target trailsTrail brilliance Thin trailsOrigin Mark Parallel Index LinesMarkers ZoomFunction Keys Presetting the user keysPresetting the function keys User Keys F1, F2, F342 FUNC1 menu Func key objectivesSuppressing Second-trace Echoes Adjusting Brilliance of Screen DataEnhanced Video Time AlarmNoise Rejector Navigation Data Degaussing IntervalOutputting Target Position Video ContrastClutter Sweep Available color combinations Background ColorSelecting Range Scales Selecting Bearing Scale FormatEnlarging Close-in Targets 46 A/D Converter Curve SettingA/D curve settings Alarms AlarmsPeformance Monitor Alarms con’tMinimum and maximum ranges Radar resolutionRadar Observation GeneralMultiple echoes False EchoesBearing accuracy Range measurementShadow sectors Sart Search and Rescue TransponderVirtual image Radar bandwidth Sart range errorsShowing Sart marks on the radar display General remarks on receiving SartSEA control Racon Radar BeaconRadar side lobes GainOn next MAINTENANCE, TroubleshootingPeriodic Maintenance Schedule Maintenance scheduleLife expectancy of major parts Maintenance schedule con’tLife Expectancy of Major Parts Easy troubleshooting Fuse Replacement Simple TroubleshootingReplacement of Batteries Battery replacement informationService call Advanced-level TroubleshootingServiceman qualification Problem Check point Remedy Probable cause Advanced-level troubleshootingAdvanced-level troubleshooting con’t Sequence for diagnostic test Diagnostic TestTest results screen Display circuit test Left side view Parts LocationDisplay unit, top view Scanner unit, left side view FR-1760DS Scanner UnitScanner unit, right side view, RF section removed FR-1760DS Scanner Unit con’tFR-1760DS Power supply unit FR-1760DS Power Supply UnitRF module Upper part FR-1710/1725 Scanner UnitModule Lower part Specifications of Marine Radar Radar Display Dimension and Mass Coating Color Racon IndexIndex-2