Appendix B
E r r o r C o d e s
Error Code | Fault |
0 | No Error |
I/O Errors |
|
1 | I/O1 Fault |
2 | I/O2 Fault |
3 | I/O3 Fault |
4 | I/O4 Fault |
5 | I/O5 Fault |
6 | An I/O is already set to this type. |
7 | Tried to set an Input or defined I/O. |
8 | Tried to set an I/O to an incorrect I/O type. |
9 | Tried to write to I/O set as input or is “TYPED”. |
10 | Illegal I/O number. |
Data Errors |
|
20 | Tried to set unknown variable or flag. |
21 | Tried to set an incorrect value. |
22 | VI set greater than or equal to VM. |
23 | VM is set less than or equal to VI. |
24 | Illegal data entered. |
25 | Variable or flag is read only. |
26 | Variable or flag is not allowed to be incremented or decremented. |
27 | Trip not defined. |
28 | Trying to redefine a program label or variable. |
29 | Trying to redefine an embedded command or variable. |
30 | Unknown label or user variable. |
31 | Program label or user variable table is full. |
Program Errors |
|
40 | Program not running. |
41 | Program running. |
42 | Illegal program address. |
43 | Tried to overflow program stack. |
Communications Errors |
|
60 | Tried to enter unknown command. |
61 | Trying to set illegal BAUD rate. |
Motion Errors |
|
80 | HOME switch not defined. |
81 | HOME type not defined. |
82 | Went to both LIMITS and did not find home |
83 | Reached positive LIMIT switch. |
84 | Reached minus LIMIT switch. |
85 | MA or MR not allowed while in motion. |
86 | Stall detected. |
65