MNEMONIC

FUNCTION

TYPE

ST

Read Only Stall Flag

Encoder Flag

DESCRIPTION

The ST flag will be set to 1 when a stall is detected. It will be cleared upon execution of another motion command.

USAGE

PR ST

BR <addr>, ST=1

CL <addr>, ST=1

EXAMPLE RESPONSE:

 

ST=0

‘motor not stalled

ST=1

‘motor stalled

RELATED COMMANDS: EE, SF, ST

MNEMONIC

 

FUNCTION

TYPE

TE

 

Trip Enable Flag

Setup Flag

DESCRIPTION

 

 

 

This flag will enable or disable specified trip functions.

 

TE=0

TI Disabled

TP Disabled

 

TE=1

TI Enabled

TP Disabled

 

TE=2

TI Disabled

TP Enabled

 

TE=3

TI Enabled

TP Enabled

 

 

 

 

 

USAGE

 

DEFAULT

 

TE= <1-4>

 

0 (Trips Disabled)

 

 

 

 

 

EXAMPLE:

 

 

 

TE=1 ‘Enable trip on input functions

 

 

 

RELATED COMMANDS: I1-I4, P, S1-S4, TI, TP

 

 

 

 

 

MNEMONIC

 

FUNCTION

TYPE

TI

 

Trip on Input

Variable

DESCRIPTION

Sets up an input event (trip) for the specified input. There are two parameters for the TI variable. The first specifies the address of the subroutine that should be executed when the input goes to true. The second specifies which input line to monitor.

USAGE

TI=<input>,<addr/label>

EXAMPLE:

 

TI=2,K1

‘execute subroutine labeled K1 when input 2 is active.

RELATED COMMANDS: I1-4, S1-4, TP