G e n e r a l S p e c i f i c a t i o n s

S o f t w a r e

 

Program and Data Storage

Non-Volatile

User Program Space

767 Bytes

User Registers

4 - 32 Bit

Math Functions

+, -, x, ÷, <>, =, <, <=, >, >=, AND, OR,

 

XOR, NOT

Branch Functions

Branch & Call (Conditional)

Predefined I/O Functions

 

Inputs

Home, Limit +, Limit -, Go, Stop, Pause,

 

Jog +, Jog -, Analog Input

Outputs

Moving, Fault

Trip Functions

Input, Position

Party Mode Node Addresses

62

Encoder Functions

Stall Detect, Position Maintenance,

P r o t e c t i o n

Find Index

 

Types

Thermal

 

 

P o w e r S u p p l y R e q u i r e m e n t s

 

Each MDrive will require a maximum power supply current of 2A. Actual power supply current will depend upon the load and duty cycle.

R e c o m m e n d e d I M S P o w e r S u p p l i e s

Listed below are the power supplies recommended for use with both voltage ranges of the MDrive17 Motion Control.

U n r e g u l a t e d L i n e a r S u p p l y

 

Input Specifications

IP404(MDI17)

 

AC Input Voltage Range

102-132VAC/Optional 240VAC

Frequency

50-60Hz

Output Specifications

 

Voltage (Nominal - No Load)

40 VDC

Current (Peak)

4 Amps

Current (Continuous)

2 Amps

U n r e g u l a t e d S w i t c h i n g S u p p l y

 

Input Specifications

ISP200-4(MDI17)

102-132VAC/Optional 240VAC

AC Input Voltage Range

Frequency

50-60Hz

Output Specifications

 

Voltage (Nominal - No Load)

45 VDC

Current (Peak)

3 Amps

Current (Continuous)

1.5 Amps

T h e r m a l S p e c i f i c a t i o n s

Because the MDrive consists of two core components, a drive and a motor, close attention must be paid to the thermal environment where the device is used. The following maximum temperatures apply to the MDrive17:

Heatsink Temperature

 

Max

85°C

Motor Temperature

 

Max

100°C

10