MNEMONIC

FUNCTION

TYPE

R1 - R4

User Registers

User Variable

DESCRIPTION

The MDrive Motion Control has four 32 bit user registers to contain numerical data. These registers may contain up to 11 digits including the sign and may be used to store and retrieve data to set variables, perform math functions, store and retrieve moves and set conditions for branches and subroutine calls.

USAGE

RANGE

DEFAULT

R<x>=<data>

-2147483647 to 2147483647

0

 

 

 

EXAMPLES:

 

 

R1=50000

‘Set Register 1 to 50000

 

‘Subroutine using a register value to perform a math function that will display axis position in revolutions rather than motor steps

‘****variable setup*****

 

MS=256

‘set resolution to 256 microsteps/step

 

P=0

‘set position counter to 0

 

R1=51200/1

‘51200 steps = 1 rev

 

*****Program Content*******

 

MR R1

‘move relative 102400 steps

 

H

‘Hold execution until motion stops

 

CL 348

‘call subroutine at address 348

 

‘******Sub at address 348******

 

R2=P

‘set Register 2 equal to the position counter

 

R3=R2/R1

‘set Register 3 equal to R2/R1

 

PR “Position = “, R3, “Revolutions”;

 

H 60000

‘hold for 1 minute

 

RT

‘return to prog

 

RELATED COMMANDS: —

MNEMONIC

FUNCTION

 

TYPE

RC

Run Current

 

Setup Variable

DESCRIPTION

 

 

 

This variable defines the motor run current in percent.

 

 

 

 

 

 

USAGE

UNITS

RANGE

DEFAULT

RC=<percent>

Percent

1to 100

25

 

 

 

 

EXAMPLE:

 

 

 

RC=75

‘Set motor run current to 75%

 

 

RELATED COMMAND: HC