Furuno FR-1710 manual Test results screen

Page 63

Control Check Bar length increases with clockwise rotation; decreases with counterclockwise rotation.

FR-1700 Series TEST

 

 

 

 

 

 

 

 

1.

Program No.

03591511**

 

2. ROM Check

OK

 

3. RAM Check

OK

 

4. Antenna Rotation

24rpm

 

5.

Tx Trigger Frequency

3000Hz

 

6.

Video Level

000

 

 

 

 

 

7.

Video Signal

OK

 

8.

Navigation I/O 1

OK

 

9.

Navigation I/O 2

OK

 

10. NMEA Heading IN

OK

 

11. LOG Pulse IN

OK

 

ARP Test

 

 

 

 

 

 

 

 

1.

Program No.

18590411**

18590421**

2. ROM Check

OK

OK

3. RAM Check

OK

 

4. Speed Log

OK 0.0 KT

 

5.

Course

OK

 

6.

Trigger

OK

 

7.

Video Signal

OK

 

8.

Bearing Pulse

OK

 

9.

Heading Pulse

OK

 

10. Minimum Hit

0003

 

 

 

11. Scan Time

0274

 

 

 

12. Manual Acq.

00

 

 

 

 

 

13. Auto Acq.

00

 

 

 

 

 

14. FE-Data 1

0000

 

 

 

15. FE-Data 2

0000

 

 

 

Press MENU key to escape.

 

 

 

 

 

 

 

 

Press ENTER key to check CRT.

 

000

 

 

 

 

 

 

 

 

 

 

 

 

 

000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

G

Y

 

P

L

W

 

 

E

B

U

 

 

R

B

H

 

R

L

R

 

E

L

L

I

X:000

E

L

P

D

E

O

U

L

U

T

Y:000

N

E

E

E

 

 

W

 

E

 

 

 

ROM Test

RAM Test

** Program No.

Press MENU key to return to radar picture.

Press ENTER/SELECT key to go picture check facility.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Trackball Confirmation

EBL Control Confirmation

Test

Figure increments upward

with up, right rotation;

(Figure increments upward

pattern

downward with down, left

with clockwise rotation;

 

 

rotation.

downward with counterclockwise

 

 

VRM Control Confirmation

rotation.)

 

 

 

 

(Figure increments upward

 

 

 

 

 

 

with clockwise rotation;

 

 

 

downward with counterclockwise

 

 

 

rotation.)

Figure 3-2 Test results screen

3-8

Image 63
Contents Marine Radar First Edition NOV Keep heater away from equipment Do not operate the equipment with wet handsDo not open the equipment Do not disassemble or modify the equipmentUse the proper fuse Table of Contents Declaration of Conformity FR-1760DS SP-1Features IntroductionWord to the Owner of This Furuno Radar FR-1760DS System ConfigurationAntenna Unit Display Unit FR-1710/1725Viii Menu TreePlot Menu Mark Disp OFF Erase VEC REF REL True VEC Time Curs RNG INT REJ OFF Stretch Enhance Contrast Auto Xii Turning on the Power Operational OverviewTransmitter on Control description Control DescriptionTuning the Receiver CRT BrillianceControl Panel Backlighting Initializing the Compass Readout Degaussing the ScreenOn-screen legends and markers On-screen Legends and MarkersPresentation Modes Selecting presentation modeCourse-up Mode Screen shows Selecting the Range ScaleEntering Own Ship’s Speed Automatic speed inputManual speed input 10 Echo stretch Pulselength, Echo StretchS1P Suppressing Sea Clutter Adjusting the SensitivityManual adjustment by the A/C SEA control Automatic adjustment by the A/C Auto controlInterference Rejector Suppressing Precipitation ClutterMeasuring range by the variable range marker VRM Measuring the RangeMeasuring Bearing Measuring range by the fixed range ringsMeasuring Range and Bearing Between Two Targets Collision Assessment by the Offset EBL18 Measuring range and bearing Between two targets Setting a Target Alarm ZoneOff-centering shift Acknowledging alarmDeactivating target alarm zone Inward and outward alarms23 Echo SIG menu Echo AveragingPlotting a target Electronic Plotting Aid EPAReading the target data True or relative vector, vector timeTarget data Terminating target plottingCPA/TCPA Alarm Setting CPA/TCPA alarm rangesSilencing CPA/TCPA audible alarm Lost target alarmTarget Trails Echo Trails Past plot pointsTrue or relative trails Displaying, erasing target trails Trail gradationSelecting trail time Restoring trailsTrail afterglow Resetting target trailsTrail brilliance Thin trailsOrigin Mark Parallel Index LinesMarkers ZoomFunction Keys Presetting the user keysPresetting the function keys User Keys F1, F2, F342 FUNC1 menu Func key objectivesSuppressing Second-trace Echoes Adjusting Brilliance of Screen DataTime Alarm Noise RejectorEnhanced Video Navigation Data Degaussing IntervalVideo Contrast Clutter SweepOutputting Target Position Available color combinations Background ColorSelecting Range Scales Selecting Bearing Scale Format46 A/D Converter Curve Setting A/D curve settingsEnlarging Close-in Targets Alarms AlarmsPeformance Monitor Alarms con’tMinimum and maximum ranges Radar resolutionRadar Observation GeneralMultiple echoes False EchoesBearing accuracy Range measurementSart Search and Rescue Transponder Virtual imageShadow sectors Radar bandwidth Sart range errorsShowing Sart marks on the radar display General remarks on receiving SartSEA control Racon Radar BeaconRadar side lobes GainOn next MAINTENANCE, TroubleshootingPeriodic Maintenance Schedule Maintenance scheduleMaintenance schedule con’t Life Expectancy of Major PartsLife expectancy of major parts Easy troubleshooting Fuse Replacement Simple TroubleshootingReplacement of Batteries Battery replacement informationAdvanced-level Troubleshooting Serviceman qualificationService call Problem Check point Remedy Probable cause Advanced-level troubleshootingAdvanced-level troubleshooting con’t Sequence for diagnostic test Diagnostic TestTest results screen Display circuit test Left side view Parts LocationDisplay unit, top view Scanner unit, left side view FR-1760DS Scanner UnitScanner unit, right side view, RF section removed FR-1760DS Scanner Unit con’tFR-1760DS Power supply unit FR-1760DS Power Supply UnitRF module Upper part FR-1710/1725 Scanner UnitModule Lower part Specifications of Marine Radar Radar Display Dimension and Mass Coating Color Racon IndexIndex-2