INSTALLING THE UV SYSTEM

1Determine appropriate indoor location of the power supply and chamber, referring to Dimensions and Layout drawing.

Power supply should be installed higher than chamber away from all water sources. Ensure adequate clearance above chamber to allow for removal of the lamp and sleeve.

2Screw chamber clamp(s) to the wall (#10 screws recommended.)

3Insert chamber and tighten clamp(s).

4Make all necessary plumbing connections referring to Dimensions and Layout drawing.

Safety cap, lamp plug and power supply figures will look slightly different than those on your system.

5Install power supply mounting bracket to wall using four #8 screws (not provided).

6Slide power supply onto

mounting bracket.

7Slide Reference card behind power supply.

8

9

Insert Lamp/

 

 

 

 

sleeve assembly

 

 

and screw into

1

chamber.

2

Caution: Over tightening will break the sleeve.

10Align connections by rotating

ring clamp (if equipped) to push lamp plug onto end of lamp.

ring clamp

9

INSTALLATION OVERVIEW

OPERATION

MAINTENANCE

WARRANTY

Image 11
Contents PUV-8 Potential Safety Measures Hazard Safety Instructions Table of Contents PUV-Basic PUV-8 PUV-16 What Model do I HAVE?General All Models SpecificationsPart Number ComponentsPart Part Model Part Number Components All ModelsDimensions and Layout Water Quality Requirements Installing the UV System Gfci Disinfecting the Water Lines Allow water to fill Installation Overview Operation Maintenance Warranty Green Yellow Flashing red Solid red Overview OperationinstallationSymptom Possible cause Possible solution TroubleshootingOverview Installation Operation Maintenancewarranty Lamp tab Sleeve bolt Operationmaintenance Warranty Our Commitment Warranty