Cisco Systems 6100 installation manual 78-5481-02 09/15/98 Installation Subtended Network

Page 11

78-5481-02 09/15/98

Installation - Subtended Network 8

If you are installing the DS3 subtending I/O card on an older MC, you will need to add the standoffs to mount the card. The following procedures describe how to add the standoffs. Figure 8-4 illustrates the procedure.

1Remove the two screws currently used to hold the backplane to the chassis above and below the DS3 connector (J48).

2Install the standoffs included with the DS3 I/O card in the same location as the screws you just removed.

3Connect the DS3 I/O card to connector J48 as shown in Figure 8-4.

4Reuse the screws removed in Step 1 to hold the DS3 I/O card to the backplane.

Cisco 6100 Set Up and Installation Manual

8-11

Image 11
Contents Cabling Configuration Subtending Installation Subtended NetworkCable Type Subtending Cable Diagram SubtendingInstalling the 6100s Installation Procedures SubtendingDS3 Subtend Card Connecting the DS3 Subtending CardDS3 Subtending Card Connector DS3 Subtend Card Standoffs Cabling the System I/O Card to the DS3 Subtend Card Installing the DS3 Subtend ModuleThick Coaxial Cable through Ferrite Bead Completing the Installation Adding Standoffs for a DS3 Card Adding a DS3 Subtend Card78-5481-02 09/15/98 Installation Subtended Network