Cisco Systems appendix Cisco 6100 Series System Cables

Page 1

C H A P T E R 3

Cisco 6100 Series System Cables

This chapter provides Network Equipment Building Systems (NEBS) compliance cabling guidelines, cabling configuration diagrams, and part numbers for the following:

Direct Connect with a POTS splitter chassis (PSC) configuration

Direct Connect without a PSC configuration

Digital Off-Hook (DOH) configuration

Subtended network configuration

Siecor asymmetric digital subscriber line (ADSL) POTS Splitter Rack-Mount Shelf

Note The fan tray backplane (connector P2) is connected to the E2A alarm contact (connector J14, pins 7 and 8) on the multiplexer chassis (MC) backplane. The fan tray alarm contacts will be wired in the installation procedures so that fan tray alarms can be transmitted to the ViewRunner management software. For more information on connecting the fan tray and the MC, refer to either the Cisco 6100 Series Direct Connect Installation Guide.

Warning Only trained and qualified personnel should be allowed to install, replace, or service this equipment.

If you are using dual-port ATU-C modules, use 64-port MC cables. However, if you plan to expand your system to quad-port xTU-C modules for future releases, you can use 128-port MC cables to make future expansion easier. The 128-port MC cables are recommended for all new installations.

For detailed port mapping tables, see Appendix C, “Port Mapping.” This appendix includes port mapping tables to build MC cables.

Cisco 6100 Series User Guide

3-1

Image 1
Contents Cisco 6100 Series System Cables Technology PSCDirect Connect with a PSC Configuration Cables Nebs Compliance Cabling GuidelinesMC to PSC Cables Kit Subassembly NumberMC to PSC Cabling Diagram with One-to-One Cables Kit Subassembly Connection Backplane Connector Cisco Part NumberMC to Two PSCs Cabling Diagram with Two-to-One Cables PSC to MDF Cables MDF Modem Kit SubassemblyPSC to Pots Service Cabling Diagram with One-to-One Cables PSC to MDF Cabling Diagram with One-to-One CablesLeft cable Two-to-Two CableJ14 or J8 Direct Connect without a PSC Configuration Cables 11 Two-to-Three Cable Two-to-Three CablesThree-to-Three Cables MC to MDF Cabling Diagram with Two-to-Three CablesThree-to-Three Cable 13 shows the three-to-three cableFive-to-Six Cables MC to MDF Cabling Diagram with Three-to-Three Cables15 shows the five-to-six cable Basic DOH Component Cables DOH Configuration Cables17 Cabling Components for a DOH Configuration 18 One-to-One Cable 19 PSC to MDF Cabling Diagram with One-to-One Cables20Cisco 6100 Series User Guide 21 shows the two-to-two cable Subtended Network Configuration Cables Subtended Cabling DiagramsBackplane System Card Cable Connections26 One-to-One Special Cable Siecor Pots Splitter Cables