Multiquip LT12D, LT12P General Safety, Light Tower Safety, fire extinguisher, first aid kit

Page 6

SAFETY INFORMATION

GENERAL SAFETY

CAUTION

NEVER operate this equipment without proper protective clothing, shatterproof glasses, respiratory protection, hearing protection, steel-toed boots and other protective devices required by the job or city and state regulations.

NEVER operate this equipment when not feeling well due to fatigue, illness or when under medication.

NEVER operate this equipment under the influence of drugs or alcohol.

NOTICE

This equipment should only be operated by trained and qualified personnel 18 years of age and older.

Whenever necessary, replace nameplate, operation and safety decals when they become difficult read.

Manufacturer does not assume responsibility for any accident due to equipment modifications. Unauthorized equipment modification will void all warranties.

NEVER use accessories or attachments that are not recommended by Multiquip for this equipment. Damage to the equipment and/or injury to user may result.

ALWAYS know the location of the nearest

fire extinguisher.

ALWAYS know the location of the nearest

first aid kit.

ALWAYS know the location of the nearest phone or keep a phone on the job site. Also, know the phone numbers of the nearest ambulance, doctor and fire department. This information will be invaluable in the case of an emergency.

LIGHT TOWER SAFETY

DANGER

NEVER use light tower in rain, snow, or areas of high humidity that could generate electrical storms.

The engine of this equipment requires an adequate free fl ow of cooling air. NEVER operate this equipment in

any enclosed or narrow area where free flow of the air is restricted. If the air fl ow is restricted it will cause injury to people and property and

serious damage to the equipment or engine.

NEVER operate the equipment in an explosive atmosphere or near combustible materials. An explosion or fire could result causing severe bodily harm or even death.

The engine fuel exhaust gases contain poisonous carbon monoxide. This gas is colorless and odorless, and can cause death if inhaled.

WARNING

NEVER disconnect any emergency or safety devices. These devices are intended for operator safety. Disconnection of these devices can cause severe injury, bodily harm or even death. Disconnection of any of these devices will void all warranties.

CAUTION

NEVER lubricate components or attempt service on a running machine.

ALWAYS ensure light tower is on level ground before use so that it cannot slide or shift around, endangering workers. Always keep immediate area free of bystanders.

ALWAYS make sure trailer is leveled with all outriggers extended before raising tower. Outriggers must remain extended while tower is up.

ALWAYS keep area behind trailer clear of people while raising and lowering mast.

PAGE 6 — LT12 SERIES LIGHT TOWER • OPERATION MANUAL — REV. #12 (01/20/09)

Image 6
Contents Models LT12D, LT12P This Manual Must Accompany the Equipment AT ALL TimesProposition 65 Warning Reporting Safety Defects NhtsaTable of Contents Specifications are subject to change without noticeSafety Information Safety Messagesfire extinguisher General SafetyLight Tower Safety first aid kitLamp Safety Engine Safety Before servicing equipmentFuel Safety Towing SafetyTransporting Safety Loading and Tie-Down on Flatbed TruckElectrical Safety Power Cord/Cable SafetyGrounding Safety Battery Safety Environmental SafetyLamp Footcandle Plot Lamp Footcandle PlotSpecifications Generator SpecificationsTrailer Specifications Engine Specifications Reference Letter Description Dimension DimensionsDimensions Length Mast Stowed Position Length Mast Deployed PositionGeneral Information Components Major Components Control Panel SideRear Control Panel Light CONTROL/BREAKERControl Panel Before Starting Indoor InstallationInspection Engine OIL CheckBattery Check Fuel CheckWipe up any spilled fuel immediately Coolant Cleaning the RadiatorAIR Cleaner FAN Belt Tension Operation in Freezing WeatherLocation of Female Connectors Starting the Engine Perkins OperationStarting the Engine Starting the Engine Lombardini/Deutz EnginesDeploying the Mast to Vertical Position Mast OperationOutriggers and Support Stands Raising the MastMast Operation Turning on the Lamps Lowering the MastStowing the Mast to Horizontal Position Rotating the MastNormal Shutdown Testing the 120 VAC Gfci ReceptacleApplying AN External Load Emergency ShutdownInspection/Maintenance MaintenanceBasic Inspection and Maintenance FrequencyGeneral Inspection Flushing OUT Radiator and Changing CoolantChanging OIL Check Cable WearReplacing Fuel Filter Servicingthe Mast RAISE/LOWER Cable SystemStorage Removal from Long Term StorageLower the mast to the horizontal resting position Maintenance Trailers Adjustable ChannelWheel HUB Adjustment Leaf Suspension Leaf Suspension ComponentsTroubleshooting Generator TroubleshootingSymptom Solution Engine Troubleshooting Symptom Possible Cause SolutionEngine revolution is not Lamp Troubleshooting Clean fixture When switch is first Checking voltage and ballast Turned onReplacement minimizes color differences Lamp starts slowly ARC does not strike Defective Lamp?Starting Lamp Troubleshooting GuideConnections Ballast RemovalLT12 Wiring Diagram S/N 902148 and below StatorBLK GRN WHT RED LT12 Wiring Diagram S/N 902149 to LT12 Wiring Diagram S/N 902149 to LT12 Wiring Diagram S/N 902626 and Above BLK BRN Blue RED WHT YEL GRN Perkins Engine Wiring Diagram Deutz Engine Wiring Diagram LT12 Control PANEL/IGNITION Wiring Diagram DEUTZ/LOMBARDINI SpecificTrailer Guidelines Common Causes for Loss of TrailerTrailer Towing Guidelines Driving Conditions Coupling to the TOW VehicleInoperable BRAKES, Lights or Mirrors Trailer Towing TipsTrailer VIN TAG Suspension System Electrical ConnectorTOW Vehicle Side View MirrorsCoupler Types Safety ChainsJackstand Ball Hitch CouplerLock washer and hitch frame Coupling theTrailer to theTow Vehicle Ball CouplerAttaching Safety Chain Connecting Trailer LightsUncoupling the Ball Hitch Pintle Hitch Coupler Pintle Coupler and Pintle HookTire Safety Unsafe Tires, Lug Nuts or WheelsCoupling Trailer to Tow Vehicle Pintle Coupler Tighten lug nuts before each tow Determining Load Limit of TrailerStep Be sure lug nuts are tight before each towDetermining Load Limit of Tow Vehicle Step Tire FundamentalsP indicates the tire is for passenger vehicles Uniform Tire Quality Grading Standards Utqgs Table A. Speed RatingLetter Rating Speed Rating Tire Repair Tire Safety TipsTable B. Tire Wear Troubleshooting Replacing Worn or Damaged TiresWheels, Bearings and Lug Nuts Lights and SignalsWheel Rims Lug Nut Torque RequirementsFigure L. Trailer to Tow Vehicle Wiring Diagram HERE’S HOW to GET Help