TECHNICAL AND PERFORMANCE DATA (MODEL 224–660)
Ratio | . . . . . . . . . . . . . . . . . . . . . | . . . . . . 34:1 (Quiet Senator Air Motor) |
Maximum fluid working pressure | . . . . . . . . . . . . . . . . . 238 bar (3400 psi) | |
Maximum air input pressure . . | . . . . . . . . . . . . . . . . . . . . . | . . . . . . . . . . . . . . . . . . . . 7 bar (100 psi) |
Pump cycles per 3.8 liters (1 gal.) | . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 | |
Recommended pump speed for continuous operation | . . . . . . . . . . . . . . . . . 40 cycles per min | |
Maximum recommended pump speed | . . . . . . . . . . . . . . . . . 60 cycles per min | |
Maximum flow | . . . . . . . . . . . . . . . . . . . . | 6 liters/min (1.6 gpm) at 60 cycles/min |
Air motor effective diameter . . | . . . . . . . . . . . . . . . . . . . . . | . . . . . . . . . . . . . . . . . . . 146 mm (5.75”) |
Stroke length | . . . . . . . . . . . . . . . . . . . . . | . . . . . . . . . . . . . . . . . . . . 120 mm (4.7”) |
Displacement pump effective area | . . . . . . . . . . . . . . . . 4.5 cm@ (0.697 in.@) | |
Maximum pump operating temperature | . . . . . . . . . . . . . . . . . . . 65.5_C (150_F) | |
Air inlet size | . . . . . . . . . . . . . . . . . . . . . | . . . . . . . . . . . . . . . . . . . . . . . 3/4 npsm(f) |
Fluid outlet size | . . . . . . . . . . . . . . . . . . . . . | . . . . . . . . . . . . . . . . . . . . . . . . 3/4 npt(m) |
Weight | . . . . . . . . . . . . . . . . . . . . . | . . . . . . . . . . . . . . . . . . . 45.5 kg (100 lb) |
Wetted parts | . Carbon Steel; E52100, 41L40, and 4140 Alloy Steel; Acetal; | |
| 304, 316 and |
Zinc and Nickel Plating;PTFEr;
PTFE
KEY: Fluid Outlet Pressure – Black Curves | A 7 bar (100 psi) Air Pressure | |
Air Consumption – Gray Curves | B | 4.9 bar (70 psi) Air Pressure |
NOTE:Recommended pump speed for continuous | C | 2.8 bar (40 psi) Air Pressure |
|
|
operation: 40 cpm
Maximum recommended pump speed (to shaded area): 60 cpm
psi |
| cycles/min |
|
| psi |
| cycles/min |
|
|
| ||
bar | 19 | 38 | 57 60 | 76 | 95 | bar | 20 | 40 | 60 | 80 |
|
|
|
|
|
| |||||||||
3600 |
|
|
|
| scfm | 3600 |
|
|
|
|
| scfm |
250 |
|
|
|
| 250 |
|
|
|
|
| ||
|
|
|
| # |
|
|
|
|
| # | ||
|
|
|
|
| m /min |
|
|
|
|
|
| m /min |
3000 |
|
|
|
| 75 | 3000 |
|
|
|
|
| 75 |
A |
|
|
| 2.10 |
|
|
|
|
| 2.10 | ||
210 |
|
|
| 210 |
|
|
|
| A | |||
|
|
|
| A |
|
| A |
|
|
|
| |
|
|
|
| 60 |
|
|
|
|
| 60 | ||
2400 |
|
|
|
| 2400 |
|
|
|
|
| ||
|
|
|
| 1.68 |
|
|
|
|
| 1.68 | ||
168 |
|
|
|
| 168 |
|
|
|
| B | ||
B |
|
| B |
|
|
|
|
|
| |||
|
|
| 45 |
|
|
|
|
|
| 45 | ||
1800 |
|
|
|
| 1800 | B |
|
|
|
| ||
|
|
|
| 1.26 |
|
|
|
| 1.26 | |||
126 |
|
|
|
| 126 |
|
|
|
| |||
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
| ||
1200 | C |
|
| C | 30 | 1200 |
|
|
|
| C | 30 |
|
|
|
|
|
|
| ||||||
84 |
|
|
| 0.84 | 84 | C |
|
|
|
| 0.84 | |
|
|
|
|
|
|
|
| |||||
600 |
|
|
|
| 15 | 600 |
|
|
|
|
| 15 |
42 |
|
|
|
| 0.42 | 42 |
|
|
|
|
| 0.42 |
0 |
|
|
|
|
| 0 |
|
|
|
|
|
|
gpm0.0 | 0.5 | 1.0 | 1.5 | 2.0 | 2.5 | gpm0.0 | 0.5 | 1.0 | 1.5 | 2.0 |
| 2.5 |
liters/min | 1.9 | 3.8 | 5.7 | 7.6 | 9.5 | liters/min | 1.9 | 3.8 | 5.7 | 7.6 |
| 9.5 |
FLUID FLOW | FLUID FLOW |
(TEST FLUID: 1900 CENTIPOISE OIL) | (TEST FLUID: 100,000 CENTIPOISE SEALANT) |
To find Fluid Outlet Pressure (bar/psi) at a specific fluid flow (lpm/gpm) and operating air pressure (bar/psi):
1.Locate desired flow along bottom of chart.
2.Follow vertical line up to intersection with selected fluid outlet pres- sure curve (black). Follow left to scale to read fluid outlet pressure.
To find Pump Air Consumption (m#/min or scfm) at a specific fluid flow (lpm/gpm) and air pressure (bar/psi):
1.Locate desired flow along bottom of chart.
2.Read vertical line up to intersection with selected air consumption curve (gray). Follow right to scale to read air consumption.
27