Monessen Hearth SS38 product features, product SPECIFICATIONS, INSTALLING ABOVE 2000 FEET

Models: SS38

1 40
Download 40 pages 57.37 Kb
Page 5
Image 5
product features

product features

SS38 Direct Vent Gas Stove

product SPECIFICATIONS

This appliance has been certified for use with either natural or propane gas. See appropriate data plates.

This appliance is not for use with solid fuels.

The appliance is approved for bedroom or bedsitting room installations.

The appliance must be installed in accordance with local codes if any. If none exist use the current installation code. ANSI Z223.1/NFPA 54 in the USA, CSA B149 in Canada.

This appliance is mobile home approved.

The appliance must be properly connected to a venting system.

The appliance is not approved for closet or recessed installations.

For alcove installation see “Clearances,” Page 8.

Optional Remote

 

Receiver

 

On/Off/RS

ON/OFF

Switch

HEAT

PILOT

FAN

OFF

Door product SPECIFICATIONS

Off/Pilot/On

Knob

Hi/Lo Knob

ST1099

Blower

Figure 1 -

SS38 Stove Controls

INSTALLING ABOVE 2000 FEET

In the USA, the appliance must be derated 4% for every 1,000 ft. above 2,000 ft elevations.

In Canada, these applications are certified for altitudes of 0 - 2,000 ft, and must be derated by 10% for installa- tions between 2,000 and 4,500 ft. (derate an additional 4% for every 1,000 ft. above 4,500 ft. elevations.)

GAS pressures

 

Natural

Propane (LP)

Inlet Minimum

4.5” w.c.

11.0” w.c.

Inlet Maximum

10.5” w.c.

13.0” w.c.

Manifold Pressure

3.5” w.c.

10.0” w.c.

Gas Specifications & ORIFICE SIZE

 

 

Max.Input

Min. Input

Orifice

Model

Fuel

BTU/h

BTU/h

Size

SS38NV

Nat.

38,000

27,000

#32

SS38PV

LP

35,000

25,000

#50

The Stratford SS38 is equipped with a variable output gas control.

46D0232

Page 5
Image 5