SS38 Direct Vent Gas Stove

STOVE INSTALLATION

1.Check gas type. The gas supply must be the same as stated on the appliance’s rating decal. If the gas supply is different from the stove, STOP! Do not install the appliance. Contact your dealer immediately.

2. To ease installation, a 30" (mm) flex line with manual shut-off valve has been provided with on this appliance. Install and attach 1/2" gas line onto shut-off valve.

3. After completing gas line connection, purge air

 

 

from gas line and test all gas joints from the gas

 

 

meter to the stove for leaks. Use a soap and water

 

 

solution or a gas sniffer.

Pressure

 

 

 

4. To adjust flame height, turn HI/LO knob to HI to get

Test “IN”

 

maximum pressure to burner. Turn HI/LO knob to

 

 

LO to get minimum pressure.

Pressure

FP1979

5. To check gas pressures at valve, turn captured

Test “OUT”

 

screw counter clockwise 2 or 3 turns and then place

HI/LO Knob

 

tubing to pressure gauge over test point. Turn unit

 

Pilot Adjustment Screw

to high. Figure 29. After taking pressure reading,

be sure and turn captured screw clockwise firmly

 

Figure 29 -

to reseal. Do not over torque. Check test points for

 

Gas Pressure Check at Gas Valve

gas leaks with a soap and water solution.

 

 

WARNING

INSTALLING LOUVERS

Do not use open flame to check for gas leaks.

Attach the top louver unit (two louvers and two louver brackets) to stove with four (4) screws provided — two (2) on each side. Figure 30. Repeat for bottom louver unit.

Louver Bracket

Louver

Bracket

Louvers Screws

Figure 30 - Installing Louvers

ST1113

22

46D0232

Page 22
Image 22
Monessen Hearth SS38 operating instructions Installing Louvers, Do not use open flame to check for gas leaks