Monessen Hearth clearances, Clearances to combustibles, SS38 Direct Vent Gas Stove

Models: SS38

1 40
Download 40 pages 57.37 Kb
Page 8
Image 8
clearances

SS38 Direct Vent Gas Stove

clearances

Clearances to combustibles

 

The dimensions shown in Figures 4 and 5 are minimum clearances to maintain

 

in installing this heater. Left and right clearances are determined when facing the

WARNING

front of the heater.

Follow these instructions carefully to ensure safe installation. Failure to follow

 

 

instructions exactly can create a fire hazard.

 

The appliance cannot be installed on a carpet, tile or other combustible material

 

other than wood flooring. If installed on carpet or vinyl flooring, the appliance

 

shall be installed on a metal, wood or noncombustible material panel extending

 

full width and depth of the appliance.

 

 

Maintain the following minimum clearances for service and maintenance.

Stove must be at least 6" from the back wall. Figure 4

Stove must be at least 9" from either side wall. See Figure 4

Stove must be at least 6" from the corner. Figure 4

No clearance is necessary to the floor. Stove may sit on the floor. Figure 5

The minimum ceiling height from the floor must be 72".

 

Back Wall

 

 

 

 

6" Min.

 

 

 

Wall

Minimum

 

 

 

Side

 

 

 

 

9"

 

 

 

 

to Either

 

 

 

 

Side Wall

6" Minimum

 

 

 

 

Clearance to

 

 

Figure 4 -

Corner

 

0"

 

 

Clearances to Side, Back and Adjacent Walls

Figure 5 -

 

Clearance to Floor

ST1102

46D0232

Page 8
Image 8