VENTING INSTALLATION

SS38 Direct Vent Gas Stove

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

V

H

H1

NOTE: Install restrictor into 4" collar of stove or first vent secton as shown.

Table 6 - Vertical Venting with Two (2) Elbows

Vertical (V)

Horizontal (H) + (H1)

Minimum

Maximum

8'

2'

9'

4'

10'

6'

11'

8'

23'

8'

Figure 24 -

Vertical Rigid Venting Configuration Using Three 90° Elbows with Two Horizontal Runs

H

V1

Table 7 - Vertical Venting with Two (2) 90°

 

 

Elbows

 

 

 

Vertical (V) + (V1)

Horizontal (H) + (H1)

 

 

V

Minimum

Maximum

 

 

8'

2'

 

 

9'

12'

 

 

10'

18'

 

 

11'

20'

 

 

Vertical Venting V = 40' maximum

NOTE: Install restrictor into 4" collar of stove or first vent secton as shown.

V

NOTE: Install restrictor into 4" collar of stove or first vent secton as shown.

 

ST1112

Figure 25 -

Figure 26 -

Vertical Rigid Venting Configuration Using

Vertical Rigid Venting Configuration

Two 90° Elbows

with No Horizontal run