Graco 206700, 206699, 206405 important safety instructions Packing Nut Adjustment

Page 11

Maintenance

Packing Nut Adjustment

WARNING

To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 8.

WARNING

Keep your hand and fingers away from the piston when it is moving. As the piston moves into the pump base it can amputate fingers or break tools caught between the moving parts. Note the pinch point shown in Fig. 3. Be sure all air and fluid pressure is fully relieved before adjusting the piston or packing nut to reduce the risk of amputation.

NOTE: Perform this adjustment if: (a) material drips steadily from the air motor weep hole, which indicates the packings are too loose, (b) the pump requires more than 50 psi (.345 MPa, 3.4 bar) air pressure to cycle when the gun is triggered, which indicates the pack- ings are too tight, or (c) the pump has been in opera- tion for 40 hours.

PISTON

PINCH POINT

BASE

Fig. 3

FLUID

OUTLET

WEEP HOLE LOCATED

OPPOSITE FLUID OUTLET

AND IN BOTTOM OF BASE

1.Relieve the pressure. Follow the Pressure Relief Procedure on page 8.

2.Using a 1/4” nut driver, remove the six screws (24) from one of the muffler plates (20 or 40) and remove the muffler plate. See Fig. 4.

3.Check to see that the air motor piston is at the top of the stroke. If it is not, first read the warning above. Then, while keeping your fingers away from moving parts, apply very low pressure air to the air inlet to move the piston up. Close the air regulator and disconnect the air supply hose. Refer to Fig. 3.

4.Use a 1/4” diameter rod, spanner wrench, or torque wrench to tighten the packing nut. First loosen the nut, then tighten snugly, and finally tighten an additional 1/2 turn (20–25 ft–lbs). See Fig. 5.

5.Replace the muffler cover, and the six screws. See Fig. 4.

6.Reconnect the air line. After the pump is started, it should run at 40 psi (.276 MPa, 2.8 bar) with no load. Startup may require additional air pressure.

BASE

20

24

Fig. 4

PACKING NUT

1/4” DIA. ROD

Fig. 5

306531Z1 11

Image 11
Contents Table of Contents Instructions-Parts ListEquipment Misuse Hazard SymbolsSkin Injection Hazard Fire and Explosion Hazard 306531Z1 System Accessories InstallationTo ground the pump GroundingOperation Pressure Relief ProcedureStarting and Adjusting the Pump 306531Z1 Lubrication MaintenanceShutdown and General Care FlushingPacking Nut Adjustment Problem Cause Solution TroubleshootingBefore you start Air Motor ServiceAir Motor & Throat Disassembly 30 31 34 † 33 † 45 † 32 † 58 53† 33† 45† ReassemblyAir Motor Service Displacement Pump Disassembly Displacement Pump ServiceDisplacement Pump Service Parts Model 206405, Series K 35 lb. pail size 20 306531Z1 Model 206699, Series J 120 lb. drum size 22 306531Z1 Mounting Hole Layout DimensionsTechnical Data Graco Phone Numbers Graco Standard Warranty