Graco 16P957, 16T311 Installation, General Information Grounding, Location

Page 8

Installation

Installation

General Information

Grounding

NOTE: Reference numbers and letters in parentheses in the text refer to the callouts in the figures.

Accessories are available from Graco. Make certain all accessories are adequately sized and pressure-rated to meet the system’s requirements.

Location

Lift location

Lift location

 

Floor

 

mounting

 

location

Floor

 

mounting

ti20230b

location

 

FIG. 4

 

Attach a lifting sling at the proper lift spots. Lift off the pallet using a crane or a forklift.

Position the ram so the air controls are easily accessi- ble. Ensure that there is enough space overhead for the ram to raise fully. See Dimensions, page 31.

Set the brake on the cart before using the system.

Model 16P957 only: Using the holes in the ram base as a guide, drill holes for 1/2 in. (13 mm) anchors.

Model 16P957 only: Ensure that the ram base is level in all directions. If necessary, level the base using metal shims. Secure the base to the floor using 1/2 in. (13

mm)anchors that are long enough to prevent the ram from tipping.

The equipment must be grounded to reduce the risk of static sparking. Static sparking can cause fumes to ignite or explode. Grounding provides an escape wire for the electric current.

Pump: use the supplied ground wire and clamp. Con- nect other end of wire to a true earth ground. See FIG. 5.

ti8250a

FIG. 5

Air and fluid hoses: use only electrically conductive hoses with a maximum of 500 ft. (150 m) combined hose length to ensure grounding continuity. Check elec- trical resistance of hoses. If total resistance to ground exceeds 25 megohms, replace hose immediately.

Air compressor: follow manufacturer’s recommenda- tions.

Spray gun/dispense valve: ground through connection to a properly grounded fluid hose and pump.

Fluid supply container: follow local code.

Object being sprayed: follow local code.

Solvent pails used when flushing: follow local code. Use only conductive metal pails that are properly grounded.

To maintain grounding continuity when flushing or relieving pressure: hold metal part of the dispense valve firmly to the side of a grounded metal pail, then trigger the valve.

8

3A2798D

Image 8
Contents Important Safety Instructions Gallon 20 liter, with cartGallon 20 liter, no cart II 2 G c T2Contents Related ManualsSkin Injection Hazard Equipment Misuse Hazard Key Component IdentificationSee on Integrated air controls include Air Line AccessoriesIntegrated Air Controls Platen Component Identification Model 16U676, 20 liter 5 gallonLocation InstallationGeneral Information Grounding Mechanical Setup Connect Mix Line and GunAttach Drum Stops IG Ram BasePressure Relief Procedure Flush Before Using EquipmentSupply System Operation Before OperatingStart and Adjust Ram Start and Adjust PumpChange Drums FlushShutdown and Care of the Pump Replace Throat SealsBefore Beginning Repair Maintenance Procedures Platen MaintenanceAdjust Spacers Use Platen with Tapered and Straight Sided PailsUse platen with straight sided pail Remove and Reinstall WiperReassemble 20 Liter Wiper Assembly Platen Assembly 411 418 412 420 419 409 414 415 406 407 402 403 405Troubleshooting RamInstall Wipers RepairDisconnect Pump from Platen Connect Platen to PumpDisconnect Displacement Pump Install Displacement PumpConnect Displacement Pump Remove Displacement PumpConnect air hose to air motor fitting 7. See Remove Air Motor Install Air MotorDisconnect air hose from air motor fitting 7. See Repair Parts Supply Unit RepairRam Piston Rods Disassemble Piston Rod Seal and BearingAssemble Piston Rod Seal and Bearing Disassemble Ram Piston22 5 PartsXtreme PFP, 16P957 and 16T311 Qty 1 4 4 1 2 1 1 1 1 1 1 Part DescriptionRAM, dual post, motor regulator Cart, 16P434 Part Description QtyPumpline 201 212 215 202 229 216 203 204 207 206 205320 305 321 318 326 307 308 312 324 304, 310 305 301 6 334 Ram Frame333 332 331 303 310 335 315 314 313 Ram Frame Parts Description Qty Part Description20L Platen, 16U676 411 418 412419 401 BASE, platen, 20L 402 276049 403 405Check Valve 16T481 1205 1206 1207 1204 1201Accessories Static Mixer Kit, 16T316 Static Mixer 16T316Dimensions Technical Data Maximum fluid working pressure3A2798D Graco Standard Warranty Graco Information