Graco 16T311, 16P957 Connect Mix Line and Gun, Attach Drum Stops, Mechanical Setup, IG Ram Base

Page 9

Installation

Connect Mix Line and Gun

NOTE: Kit 24P832 includes items 5, 6, and 11-16 in FIG. 6.

1.If installing mix line and gun kit 24P832, install nipple (5), check valve (6), and second nipple (5) onto the pump outlet as shown in FIG. 6.

2.Connect the supplied 3/4 in. hose (11) to the nipple (5). See FIG. 6.

3.Use reducing nipple (12) to connect the supplied 1/2 in. whip hose (13) to the 3/4 in. hose (11).

4.Use nipple (14) to connect gun swivel (15) to whip hose (13).

5.Connect gun (16) to gun swivel (15).

16

15

14

13

12

11

5

6

5

 

ti20229b

FIG. 6

NOTE: Quick disconnects restrict flow for large air motors.

Attach Drum Stops

This unit is shipped with drum stops in place to help position the drum on the ram. For replacement parts, order Kit 255477. The kit includes 2 each of capscrews (FA), lock washers (not shown), and drum stops (FB).

FA

ti20248b

FB

 

FIG. 7

1.Locate the correct set of mounting holes on the ram base.

2.Using the capscrews (FA) and lock washers (not shown), attach the drum stops (FB) to the ram base.

NOTE: Only use the 5 gallon drum stop position shown in FIG. 8.

Mechanical Setup

1. Fill displacement pump wet cup 2/3 full with Graco

Throat Seal Liquid (TSL).5 gal (20 L)

2.Back-off air regulators to their full counterclockwise position and close all shutoff valves.

3.Connect air line from an air source to the system air

inlet. See FIG. 1. Use a supply hose capable of

FIG. 8: Ram Base

meeting the required flow.

3A2798D

9

Image 9
Contents Gallon 20 liter, with cart Important Safety InstructionsGallon 20 liter, no cart II 2 G c T2Related Manuals ContentsSkin Injection Hazard Equipment Misuse Hazard Component Identification See onKey Air Line Accessories Integrated Air ControlsIntegrated air controls include Model 16U676, 20 liter 5 gallon Platen Component IdentificationInstallation General Information GroundingLocation Connect Mix Line and Gun Mechanical SetupAttach Drum Stops IG Ram BaseFlush Before Using Equipment Pressure Relief ProcedureSupply System Operation Before OperatingStart and Adjust Pump Start and Adjust RamFlush Change DrumsShutdown and Care of the Pump Replace Throat SealsPlaten Maintenance Before Beginning Repair Maintenance ProceduresAdjust Spacers Use Platen with Tapered and Straight Sided PailsRemove and Reinstall Wiper Reassemble 20 Liter Wiper AssemblyUse platen with straight sided pail 411 418 412 420 419 409 414 415 406 407 402 403 405 Platen AssemblyRam TroubleshootingRepair Install WipersDisconnect Pump from Platen Connect Platen to PumpInstall Displacement Pump Disconnect Displacement PumpConnect Displacement Pump Remove Displacement PumpRemove Air Motor Install Air Motor Disconnect air hose from air motor fitting 7. SeeConnect air hose to air motor fitting 7. See Supply Unit Repair Repair PartsRam Piston Rods Disassemble Piston Rod Seal and BearingDisassemble Ram Piston Assemble Piston Rod Seal and BearingParts Xtreme PFP, 16P957 and 16T31122 5 Part Description RAM, dual post, motor regulatorQty 1 4 4 1 2 1 1 1 1 1 1 Part Description Qty Cart, 16P434201 212 215 202 229 216 203 204 207 206 205 PumplineRam Frame 333 332 331 303 310 335 315 314 313320 305 321 318 326 307 308 312 324 304, 310 305 301 6 334 Qty Part Description Ram Frame Parts Description411 418 412 20L Platen, 16U676419 401 BASE, platen, 20L 402 276049 403 4051205 1206 1207 1204 1201 Check Valve 16T481Static Mixer Kit, 16T316 Static Mixer 16T316 AccessoriesDimensions Maximum fluid working pressure Technical Data3A2798D Graco Information Graco Standard Warranty