Installation
Connect Mix Line and Gun
NOTE: Kit 24P832 includes items 5, 6, and
1.If installing mix line and gun kit 24P832, install nipple (5), check valve (6), and second nipple (5) onto the pump outlet as shown in FIG. 6.
2.Connect the supplied 3/4 in. hose (11) to the nipple (5). See FIG. 6.
3.Use reducing nipple (12) to connect the supplied 1/2 in. whip hose (13) to the 3/4 in. hose (11).
4.Use nipple (14) to connect gun swivel (15) to whip hose (13).
5.Connect gun (16) to gun swivel (15).
16
15
14
13
12
11
5 | 6 | 5 |
| ti20229b |
FIG. 6
NOTE: Quick disconnects restrict flow for large air motors.
Attach Drum Stops
This unit is shipped with drum stops in place to help position the drum on the ram. For replacement parts, order Kit 255477. The kit includes 2 each of capscrews (FA), lock washers (not shown), and drum stops (FB).
FA
ti20248b | FB |
|
FIG. 7
1.Locate the correct set of mounting holes on the ram base.
2.Using the capscrews (FA) and lock washers (not shown), attach the drum stops (FB) to the ram base.
NOTE: Only use the 5 gallon drum stop position shown in FIG. 8.
Mechanical Setup
1. Fill displacement pump wet cup 2/3 full with Graco
Throat Seal Liquid (TSL™).5 gal (20 L)
2.
3.Connect air line from an air source to the system air
inlet. See FIG. 1. Use a supply hose capable of | FIG. 8: Ram Base |
meeting the required flow. |
3A2798D | 9 |