Siemens SG-6048-01 manual Appendices, Appendix a Block Diagram

Page 16

Appendices

Appendix A: Block Diagram

The illustration below is a block diagram showing how the Isolated Multi-Drop converter operates. The diagram identifies the internal components that make up the converter.

 

 

 

 

 

Galvanically Isolated

 

 

 

 

 

 

 

RS-485 Logic

 

 

 

 

RS-232

 

 

 

RS-485

 

 

 

25-pin D

 

 

 

Transceiver (4)

 

 

 

Transceiver

 

 

 

 

 

 

 

Connector

 

 

 

 

+

 

 

 

 

 

 

 

RS-485

 

 

 

 

 

 

 

 

 

3

 

 

Tx Enable

SHIELD

 

RXD

 

 

Port 1

 

 

 

 

 

 

-

 

 

TXD

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RS-232

RTS

4

 

 

 

 

+

RS-485

Connector

 

 

 

Tx Enable

SHIELD

Port 2

 

 

 

-

 

 

8

 

 

 

 

 

 

DCD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Signal

7

 

 

 

 

+

 

 

Ground

 

 

 

 

 

RS-485

 

 

 

 

 

Tx Enable

SHIELD

 

 

 

 

 

Port 3

 

 

 

 

 

 

 

-

 

 

 

 

 

 

 

 

+

RS-485

 

 

 

 

 

Tx Enable

SHIELD

 

 

 

 

 

 

 

-

Port 4

 

 

 

 

 

 

 

 

 

 

 

Tx

 

 

 

 

 

 

 

Baud

Enable

 

 

Earth Ground

 

 

 

 

Logic

 

 

 

 

 

 

Switch

 

 

 

 

 

 

 

 

RTS/DCD

AUTO/MAN

Opto-isolators

 

 

 

 

RTS

 

 

 

 

DCD

MAN

for each data

 

 

 

 

 

channel

 

 

 

 

 

 

AUTO

 

 

 

 

 

 

 

 

5V

 

 

 

 

 

 

 

 

Power Supply

 

 

 

 

 

 

 

 

 

DC

 

Isolated

 

 

120 VAC/

 

 

5V

 

Supply

 

 

 

 

 

 

 

 

 

125 VDC

 

 

 

DC

 

 

 

 

 

 

 

 

 

 

Source

 

 

 

 

 

 

 

 

 

 

 

15V

 

+

External 15V DC output

 

 

 

 

 

 

 

-

 

 

 

 

 

 

 

 

 

 

 

 

 

Earth Ground

 

 

 

 

 

Figure A.1. Block Diagram

Siemens Energy & Automation, Inc.

13

Image 16
Contents Isolated Multi-DropConverter Operator’s ManualQualified Person Contents How to Use This Manual IntroductionIntroduction Product SummarySetting Up the Converter Setting Up the ConverterOperating in Manual Mode Installing the Converter Installing the ConverterGetting Ready Preparing the RS-485 CableConnecting Directly to a PC Connecting with Short-Haul Modems Connecting With Short-Haul ModemsConnecting with Dial-Up Modems Modem Isolated Multi-Drop ConverterTesting Access Devices Testing Access DevicesTesting Static Trip III in Type RL Circuit Breaker Prepare CableTesting Static Trip III on Desktop Testing Samms on Desktop Samms Troubleshooting TroubleshootingTroubleshooting Appendix a Block Diagram AppendicesAppendices Appendix B Mounting Dimensions Appendices Siemens Energy Automation, Inc