Lowrance electronic X-65 manual Power Connections

Page 4

After the cables have been routed, fill the hole with a good marine sealing compound. Offset the bracket to cover the hole. Route the power cable through the slot. Break out one of the holes in the back of the bracket for the transducer cable.

FRONT

POWER CONNECTIONS

The X-65 works from a twelve-volt battery system. For the best results, attach the power cable directly to the battery. You can attach the power cable to an accessory or power buss, however you may have problems with electrical interference. Therefore, it’s safer to go ahead and attach the power cable directly to the battery. If the cable is not long enough, splice #18 gauge wire onto it. The power cable has two wires, red and black. Red is the positive lead, black is negative or ground. Make certain to attach the in-line fuse holder to the red leadas close to the power source as possible. For example, if you have to extend the power cable to the battery or power buss, attach one end of the fuse holder directly to the battery or power buss. This will protect both the unit and the power cable in the event of a short. The X-65 Plus requires a 3-amp fuse.

IMPORTANT!

Do not use this product without a 3-amp fuse wired into the power cable! Failure to use a 3-amp fuse will void your warranty.

If you’re installing a speed/temperature sensor, read it's mounting instruc- tions. Route the sensor’s cable to the X-65's power cable and plug it into the connector marked “SPEED/TEMP CABLE”

4

Image 4
Contents Installation and Operation Instructions Table of Contents Specifications MountingPower Connections Transducer Installation Keyboard LowranceMenus POWER/LIGHTSModes Split Chart Full ChartDigital/Chart Window Groups Automatic SensitivityRange Automatic Range ManualUpper and Lower Limits Zoom Automatic Mode ZoomZoom Manual Mode GraylineChart Speed Fish ID FishtrackChart Setup FastrakGroups Fastrack Chart CursorDisplay Zoom BAR Display Zone BAR Digital SonarAlarms Depth AlarmsZone Alarm Fish AlarmAdjust Chart Surface Clarity ASP Advanced Signal ProcessingSystem Setup Audio/DisplayReset Distance Log Temperature GraphSystem Information Units of MeasureSimulator Preset OptionsKeel Offset Calibrate Speed Windows Summary Unit won’t turn on Unit freezes, locks up, or operates erraticallyNo fish arches when the Fish ID feature is off Noise Lowrance ELECTRONICS, INC Full ONE-YEAR Warranty UPS Return Service Authorization RA NumberAccessory Ordering Information Keep this LabelPage How to Obtain Service How to Obtain Service U.S.A. Only