Lowrance electronic X-65 manual Range Automatic, Range Manual

Page 11

The sensitivity menu has left and right arrows, plus a horizontal bar graph. The graph gives a visual indication of the sensitivity level. The number to the right of the bar graph shows the percentage of sensitivity in use.

To increase the sensitivity level, press the right arrow key. As you press the key, the menu’s bar graph will grow wider and the percentage will increase in value. You can also see the difference on the chart record as it scrolls. When the sensitivity is at the desired level, release the key.

To decrease the sensitivity level, press the left arrow key. The bar graph and percentage will decrease. When the sensitivity is at the desired level, release the key. When you reach either the maximum or minimum limit, a tone sounds.

To erase the menu, press the EXIT key.

RANGE - Automatic

When turned on for the first time, the X-65 automatically places the bottom signal in the lower half of the screen. This is called Auto Ranging and is part of the automatic function. Typically, the range cannot be changed manu- ally while the unit is in automatic, as shown at right. However, depending upon the bottom depth and the current range, you can change the range to a different depth. In the example screen shown below, the bottom depth has

descended to a point where you can change the range to 150 feet. To do this, simply press the right arrow key while the Auto Range menu is displayed. When you're finished with

this menu, press the EXIT key to erase it.

RANGE - Manual

The X-65 gives you complete control over the range when it’s in the manual mode.

To change the range, first make cer- tain the X-65 is in the manual mode. Next, press the MENU key and the up or down arrow keys until the range

11

Image 11
Contents Installation and Operation Instructions Table of Contents Mounting SpecificationsPower Connections Transducer Installation Lowrance KeyboardModes POWER/LIGHTSMenus Digital/Chart Full ChartSplit Chart Window Groups Sensitivity AutomaticRange Manual Range AutomaticUpper and Lower Limits Zoom Zoom Automatic ModeGrayline Zoom Manual ModeChart Speed Fishtrack Fish IDFastrak Chart SetupDisplay Zoom BAR Chart CursorGroups Fastrack Digital Sonar Display Zone BARDepth Alarms AlarmsFish Alarm Zone AlarmASP Advanced Signal Processing Adjust Chart Surface ClarityAudio/Display System SetupUnits of Measure Reset Distance LogTemperature Graph System InformationKeel Offset Preset OptionsSimulator Calibrate Speed Windows Summary Unit freezes, locks up, or operates erratically Unit won’t turn onNo fish arches when the Fish ID feature is off Noise Lowrance ELECTRONICS, INC Full ONE-YEAR Warranty Authorization RA Number UPS Return ServiceKeep this Label Accessory Ordering InformationPage How to Obtain Service How to Obtain Service U.S.A. Only