ClearOne comm GT1524 operation manual Appendix B Pinouts, Control/Status port pinout female

Page 25

20

Appendix B: Pinouts

Appendix B ~ Pinouts

13

1

2514

Figure B.1. DB-25 connector

All commands are momentary.

The first 16 pins of the

Control/Status

port are

 

programmable

through

direct serial port commands.

5 1

9 6

Figure B.2. RS-232 connector

Control/Status port pinout (female)

Pin

Definable

Type

Default Description

1

Yes

Control

Aux In to Aux Out toggle

2

Yes

Status

Status of Aux In to Aux Out

3

Yes

Control

Mute Mic/Line In toggle

4

Yes

Status

Status of Mic/Line In mute

5

Yes

C

Telephone On/Off toggle

6

Yes

S

Status of tel. On/Off toggle

7

Yes

C

Auto Answer toggle

8

Yes

S

Status of Auto Answer

9

Yes

C

Mute Line Out toggle

10

Yes

S

Status of Line Out mute

11

Yes

C

Mute 4-Wire In toggle

12

Yes

S

Status of 4-Wire In mute

13

Yes

C

Volume up Speaker/Line (1dB)

14

Yes

S

No connection

15

Yes

C

Volume down Spkr/Line (1dB)

16

Yes

S

No connection

17

No

S

No connection

18

No

S

No connection

19

No

S

No connection

20

No

S

No connection

21

No

S

Ring indication

22

No

S

No connection

23

No

S

+5VDC

24

No

S

+5VDC

25

No

Ground

Ground

 

 

 

 

RS-232 COM DCE port pinout (female)

Pin Number

Control

Pin Number

Control

 

 

1

DCD

6

DSR

 

 

2

TXD

7

CTS

 

 

3

RXD

8

RTS

 

 

4

DTR

9

No connection

 

 

5

Ground

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760

Image 25
Contents Audio Products GT1524 Single Channel Echo Canceller GT1524 Single Channel Echo Canceller GT1524 Installation ClearOne Part No June 2002 Rev Iii Table of ContentsAppendices Introduction FeaturesSales and Customer Service Professional Services GroupTechnical Support ClearOne Communications EuMEA GmbHControls and Connections UnpackingFront panel Introduction ~ Controls and Connections Rear panelOperational Requirements Equipment placementTelephone line requirements Introduction ~ Operational RequirementsTechnical Services Group ~ 1-800-283-5936 USA ~ Connecting the unit Hardware SetupMenu trees LCD ProgrammingAdjusting a value Installation ~ LCD ProgrammingPower-Up Screen Inputs Aux In, 4-Wire In, and From TelcoMic/Line Outputs Speaker/Line Out, 4 Wire Out, and To TelcoSystem Aux OutRS-232 Set PasscodeTelco Default Meter TimeoutMeters Unit ID NumberTo adjust the volume Controlling volumeFront Panel Control MutingAnswering a call Disconnecting a callMaking a call Operation ~ Front Panel ControlCustom controller options Custom ControlOperation ~ Custom Control Technical Services Group ~ 1-800-283-5936 USA ~ Appendices Appendix a SpecificationsControl/Status port pinout female Appendix B PinoutsRS-232 COM DCE port pinout female Command structure Appendix C Serial CommandsError codes Appendix C ~ Serial CommandsGT1524 Serial Commands Explanation AGCReturn values Baud AuxmixDfltm ERL DialErle FPP FlowGain Hook Appendix C ~ Serial Commands ExampleHookd LFPMHP LVLMline NLP MuteNull Ringen RingRxrd Return valueTerl TamodeTerle UID ToutVER This Warranty is Void if WarrantyFCC Part 15 compliance Appendix E ComplianceFCC Part 68 compliance Appendix E ~ Compliance Industry Canada complianceLimits Index Index ~ S-Z