ClearOne comm GT1524 operation manual Ringen, Rxrd, Return value

Page 35

30

Appendix C ~ Serial Commands

PP

This command changes or reports back the state of the phantom power for a

microphone. Command form: PP <X>

Explanation

Value

0

= Sets the state to Off

 

1

= Sets the state to On

Null = Returns the current state

Return values

The command will return the updated condition (On=1, Off=0) of the phantom

power in the same format as the command.

RING

This command reports the presence of a Ring on the Telco port. (This is an indication

only.) Command form: RING

Return value

The Ring is sent if a valid ring has been sensed on the Telco line: RING

RINGEN

This command changes or reports back the state of the Ring Indication.

Command form: RINGEN <X>

Explanation

Value

0

= Sets the state to Off

 

1

= Sets the state to Ring 1

 

2

= Sets the state to Ring 2

 

3

= Sets the state to Ring 3

 

4

= Sets the state to Ring 4

Null = Returns the current state

Return values

The command will return the updated condition of the Ring Indication in the same

format as the command.

RXRD

This command controls or reports the Receive Reduction control of the unit.

Command form: RXRD <X>

Explanation

Values

0

= Sets Receive Reduction to Off

 

1

= Sets Receive Reduction to On

 

2

= Toggles the current state

Null = Reports back the current state

Return values

The command returns the updated connection state of the unit in the same format as

the command.

Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760

Image 35
Contents Audio Products GT1524 Single Channel Echo Canceller GT1524 Single Channel Echo Canceller GT1524 Installation ClearOne Part No June 2002 Rev Iii Table of ContentsAppendices Introduction FeaturesClearOne Communications EuMEA GmbH Professional Services GroupSales and Customer Service Technical SupportFront panel UnpackingControls and Connections Introduction ~ Controls and Connections Rear panelIntroduction ~ Operational Requirements Equipment placementOperational Requirements Telephone line requirementsTechnical Services Group ~ 1-800-283-5936 USA ~ Connecting the unit Hardware SetupMenu trees LCD ProgrammingAdjusting a value Installation ~ LCD ProgrammingPower-Up Screen Mic/Line Aux In, 4-Wire In, and From TelcoInputs Aux Out Speaker/Line Out, 4 Wire Out, and To TelcoOutputs SystemTelco Set PasscodeRS-232 Unit ID Number TimeoutDefault Meter MetersMuting Controlling volumeTo adjust the volume Front Panel ControlOperation ~ Front Panel Control Disconnecting a callAnswering a call Making a callOperation ~ Custom Control Custom ControlCustom controller options Technical Services Group ~ 1-800-283-5936 USA ~ Appendices Appendix a SpecificationsRS-232 COM DCE port pinout female Appendix B PinoutsControl/Status port pinout female Appendix C ~ Serial Commands Appendix C Serial CommandsCommand structure Error codesGT1524 Serial Commands Return values AGCExplanation Dfltm AuxmixBaud Erle DialERL Gain FlowFPP LFP Appendix C ~ Serial Commands ExampleHook HookdMline LVLMHP Null MuteNLP Return value RingRingen RxrdTerle TamodeTerl VER ToutUID This Warranty is Void if WarrantyFCC Part 68 compliance Appendix E ComplianceFCC Part 15 compliance Appendix E ~ Compliance Industry Canada complianceLimits Index Index ~ S-Z