ClearOne comm GT1524 operation manual Tout, Uid, Ver

Page 37

32

Appendix C ~ Serial Commands

TOUT

This command sets or reports the current inactivity timeout before returning to the menu screen used by the unit. Command form: TOUT <X>

Explanation

Value

0 = Disables inactivity timeout

 

1–15 = Sets the number of minutes specified

 

Null = Returns the current number of minutes

Return Values

The command will return the current timeout value. If the command changed the timeout, the updated timeout is returned.

UID

This command returns the unique ID number, the device type, and the device number of the GT1524. This command is read only. The unique ID number is preprogrammed at the factory and is unique to the unit. Command form: UID

Return Values

UID returns the device type and unique ID number. The unique ID is composed of an eight-digit hex number assigned at the factory to uniquely identify the unit.

Example

The following command requests the unit ID from device: UID

The following is returned out the serial port: UID A4EF906C

VER

This command returns the current version of software. This version is unique to a released version of software and is comprised of the DSP, the FPGA, and HC11 software. This command is read only. VER

Return Values

VER returns the version of software in the same format as the command. The Version is composed of a major version number followed by a period and a minor version number.

Example

The following command requests the software version: The following is returned out

the serial port: VER 2.0

Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760

Image 37
Contents Audio Products GT1524 Single Channel Echo Canceller GT1524 Single Channel Echo Canceller GT1524 Installation ClearOne Part No June 2002 Rev Iii Table of ContentsAppendices Introduction FeaturesSales and Customer Service Professional Services GroupTechnical Support ClearOne Communications EuMEA GmbHControls and Connections UnpackingFront panel Introduction ~ Controls and Connections Rear panelOperational Requirements Equipment placementTelephone line requirements Introduction ~ Operational RequirementsTechnical Services Group ~ 1-800-283-5936 USA ~ Connecting the unit Hardware SetupMenu trees LCD ProgrammingAdjusting a value Installation ~ LCD ProgrammingPower-Up Screen Inputs Aux In, 4-Wire In, and From TelcoMic/Line Outputs Speaker/Line Out, 4 Wire Out, and To TelcoSystem Aux OutRS-232 Set PasscodeTelco Default Meter TimeoutMeters Unit ID NumberTo adjust the volume Controlling volumeFront Panel Control MutingAnswering a call Disconnecting a callMaking a call Operation ~ Front Panel ControlCustom controller options Custom ControlOperation ~ Custom Control Technical Services Group ~ 1-800-283-5936 USA ~ Appendices Appendix a SpecificationsControl/Status port pinout female Appendix B PinoutsRS-232 COM DCE port pinout female Command structure Appendix C Serial CommandsError codes Appendix C ~ Serial CommandsGT1524 Serial Commands Explanation AGCReturn values Baud AuxmixDfltm ERL DialErle FPP FlowGain Hook Appendix C ~ Serial Commands ExampleHookd LFPMHP LVLMline NLP MuteNull Ringen RingRxrd Return valueTerl TamodeTerle UID ToutVER This Warranty is Void if WarrantyFCC Part 15 compliance Appendix E ComplianceFCC Part 68 compliance Appendix E ~ Compliance Industry Canada complianceLimits Index Index ~ S-Z