ClearOne comm GT1524 operation manual Auxmix, Baud, Dfltm

Page 29

24

Appendix C ~ Serial Commands

AUXMIX

This command changes or reports back the state of the Aux Mix Out.

Command form: AUXMIX <CH> <X>

Explanation

Channel

1

= Mic/Line In, 2= Aux In

Value

0

= Sets state to Off, 1 = Sets the state to On

Return values

The command will return the updated condition of the Aux Mix in the same format

as the command.

BAUD

This command selects or returns the baud rate for the RS-232 port on the GT1524.

Command form: BAUD <X>

Explanation

Value

1

= Selects 9,600 baud (bps) rate

 

2

= Selects 19,200 baud (bps) rate

 

3

= Selects 38,400 baud (bps) rate

 

Null = Returns the baud (bps) rate

Return values

The command will return the updated condition (1 = 9,600 baud, 2 = 19,200 baud,

3 = 38,400 baud) of the RS-232 baud rate in the same format as the command.

DFLTM

This command changes and reports back the status of the default meter.

Command form: DFLTM <CH> <X>

Explanation

Channel

1 = Mic/Line Input, Line Ooutput

 

2

= Aux Input, Aux Output

 

3

= 4 Wire Input, 4 Wire Output

 

4

= Telco Input, Telco Output

Value

I = Specifies an input channel

 

O = Specifies an output channel

Return values

The command will return the current default meter in the same format as the

command.

Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760

Image 29
Contents Audio Products GT1524 Single Channel Echo Canceller GT1524 Single Channel Echo Canceller GT1524 Installation ClearOne Part No June 2002 Rev Iii Table of ContentsAppendices Introduction FeaturesSales and Customer Service Professional Services GroupTechnical Support ClearOne Communications EuMEA GmbHFront panel UnpackingControls and Connections Introduction ~ Controls and Connections Rear panelOperational Requirements Equipment placementTelephone line requirements Introduction ~ Operational RequirementsTechnical Services Group ~ 1-800-283-5936 USA ~ Connecting the unit Hardware SetupMenu trees LCD ProgrammingAdjusting a value Installation ~ LCD ProgrammingPower-Up Screen Mic/Line Aux In, 4-Wire In, and From TelcoInputs Outputs Speaker/Line Out, 4 Wire Out, and To TelcoSystem Aux OutTelco Set PasscodeRS-232 Default Meter TimeoutMeters Unit ID NumberTo adjust the volume Controlling volumeFront Panel Control MutingAnswering a call Disconnecting a callMaking a call Operation ~ Front Panel ControlOperation ~ Custom Control Custom ControlCustom controller options Technical Services Group ~ 1-800-283-5936 USA ~ Appendices Appendix a SpecificationsRS-232 COM DCE port pinout female Appendix B PinoutsControl/Status port pinout female Command structure Appendix C Serial CommandsError codes Appendix C ~ Serial CommandsGT1524 Serial Commands Return values AGCExplanation Dfltm AuxmixBaud Erle DialERL Gain FlowFPP Hook Appendix C ~ Serial Commands ExampleHookd LFPMline LVLMHP Null MuteNLP Ringen RingRxrd Return valueTerle TamodeTerl VER ToutUID This Warranty is Void if WarrantyFCC Part 68 compliance Appendix E ComplianceFCC Part 15 compliance Appendix E ~ Compliance Industry Canada complianceLimits Index Index ~ S-Z