Appendix C ~ Serial Commands

25

DIAL

This command generates DTMF tones. This capability remains active after the call is

placed so tones can be issued for use with voice mail and pagers.

Command form: DIAL <STRING>

Explanation

STRING

is any valid combination of touch tone characters. A comma

 

indicates a two-second pause. STRING has a maximum length

 

of 15 characters. Valid characters are 0 through 9, A through

 

D, *, # and “,”.

Return values

DIAL returns the dialed string of numbers. For example, the following command

dials the number 801-975-7200: DIAL 9,8019757200 A “9” and a pause are

generated to get an outside line on a PBX. The following is returned out the serial

port: DIAL 9,8019757200

EC

This command changes or reports back the state of the echo canceller.

Command form: EC <X>

Explanation

Value

0= Sets the state to Off

 

1 = Sets the state to On

 

Null = Returns the current state

Return values

The command will return the updated condition (On=1, Off=0) of the echo canceller

in the same format as the command.

ERL

This command reports back the echo return loss (ERL) in dB.

Command form: ERL

Return Values

The command will return the ERL in the same format as the command (ERL 20).

ERLE

This command reports back the echo return loss enhancement (ERLE) in dB.

Command form: ERLE

Return values

The command will return ERLE in the same format as the command (ERLE 20).

Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760

Image 30
Contents Audio Products GT1524 Single Channel Echo Canceller GT1524 Single Channel Echo Canceller GT1524 Installation ClearOne Part No June 2002 Rev Table of Contents IiiAppendices Features IntroductionTechnical Support Professional Services GroupSales and Customer Service ClearOne Communications EuMEA GmbHUnpacking Controls and ConnectionsFront panel Rear panel Introduction ~ Controls and ConnectionsTelephone line requirements Equipment placementOperational Requirements Introduction ~ Operational RequirementsTechnical Services Group ~ 1-800-283-5936 USA ~ Hardware Setup Connecting the unitLCD Programming Menu treesInstallation ~ LCD Programming Adjusting a valuePower-Up Screen Aux In, 4-Wire In, and From Telco InputsMic/Line System Speaker/Line Out, 4 Wire Out, and To TelcoOutputs Aux OutSet Passcode RS-232Telco Meters TimeoutDefault Meter Unit ID NumberFront Panel Control Controlling volumeTo adjust the volume MutingMaking a call Disconnecting a callAnswering a call Operation ~ Front Panel ControlCustom Control Custom controller optionsOperation ~ Custom Control Technical Services Group ~ 1-800-283-5936 USA ~ Appendix a Specifications AppendicesAppendix B Pinouts Control/Status port pinout femaleRS-232 COM DCE port pinout female Error codes Appendix C Serial CommandsCommand structure Appendix C ~ Serial CommandsGT1524 Serial Commands AGC ExplanationReturn values Auxmix BaudDfltm Dial ERLErle Flow FPPGain Hookd Appendix C ~ Serial Commands ExampleHook LFPLVL MHPMline Mute NLPNull Rxrd RingRingen Return valueTamode TerlTerle Tout UIDVER Warranty This Warranty is Void ifAppendix E Compliance FCC Part 15 complianceFCC Part 68 compliance Industry Canada compliance Appendix E ~ ComplianceLimits Index Index ~ S-Z