Calibrating the Expression Pedal
If the Expression Pedal’s range becomes diminished over time, it may be necessary to
1.Begin with the power disconnected from the Expression FactoryTM.
2.Select Model 1 using the MODEL knob.
3.Insert a standard mono (TS) guitar cable into the FOOTSWITCH jack.
4.Connect the power supply to the Expression Factory. The INDICA- TOR LED begins flashing green.
5.Rock the expression pedal forward (toe down).
6.Select Model 2 using the MODEL knob. The INDICATOR LED begins flashing yellow.
7.Rock the expression pedal back (toe up).
8.Select Model 3 using the Model knob. The INDICATOR LED should flash green three times if calibration was successful.
If the calibration procedure fails, the INDICATOR LED will flash red instead of green during step 8 and the unit will not return to normal operation until the Expression Pedal has been properly calibrated. Select Model 1 using the MODEL knob at this time and repeat steps