Sony PCS-1P For loading of application, For command input, To stop setting, Contents of functions

Page 60

For loading of application

1.Display a service menu.

2.Insert the Memory Stick, in which the application software of the version to be loaded is recorded, into a

Memory Stick slot.

3. Select “Load application” using , , , and buttons of a remote controller and press the decide button.

4.A confirmation message on whether to execute is displayed.

5.To execute, select “OK” and press the decide button. The screen display during loader execution then appears. After completion, a launcher menu is displayed. To cancel execution, select “Cancel” and press the decide button. The current display returns to a service menu.

6.Push in the Memory Stick once and take out it.

n

Do not turn off the power or take out a Memory Stick until the launcher menu is displayed.

For command input

1.

Display a service menu.

2.

Select “Command” using , , , and buttons of a

remote controller and press the decide button. A key guidance is then displayed.

3.Enter the commands in a command list from a remote controller.

m

.To set two or more commands, put a one-character blank between the commands and then enter them.

.Set only one type of LAN interface. If not, the LAN interface does not operate normally.

4. Select “Save” using , , , and buttons of a remote controller and press the decide button.

A set menu is then displayed.

5.When a LAN interface is set (including the case where the setting is returned to the initial value), restart the main unit using the power switch of a communication terminal.

To stop setting

Select “Cancel” using , , , and buttons of a remote controller and press the decide button, or press the return button of a remote controller.

n

Do not enter commands other than shown in a command list. The internal operation mode may be changed in this case.

2-30

Contents of functions

1)Commands

The internal operation mode of the main unit is changed for a test and service.

Command list

Command

Contents

 

 

100F

Sets a LAN interface to the 100BASE

 

full-duplex mode.

100H

Sets a LAN interface to the 100BASE

 

half-duplex mode.

10F

Sets a LAN interface to the 10BASE full-

 

duplex mode.

10H

Sets a LAN interface to the 10BASE

 

half-duplex mode.

TOS1 to

Sets the Type Of Service (TOS) bit value

TOS255

to a transmission packet.

 

Consult the network administrator for

 

the set value.

Blank (The

Set using an initial value.

input value

The LAN interface mode is Auto

above is

Negotiation.

cleared.)

Reception packet loss indicator

 

display ON

 

TOS0

 

 

m

.To set two or more commands, put a one-character blank between the commands.

.Set only one type of LAN interface. If not, the LAN interface does not operate normally.

.The enabled command can be confirmed in a command column at all times.

.Do not enter commands other than shown in a command list. The internal operation mode may be changed in this case.

PCS-1/PCS-1P

Image 60
Contents PCS-1 PCS-1P Warnung Table of Contents Technical Data Lay Out the Videoconferencing Room Camera RangeTop view horizontal range at maximum zoom- out Side view vertical range at maximum zoom-outHighly directional range of microphone Microphone layout examples Installation of document stand PCS-1/PCS-1P Operating Environment Layout ConsiderationsLighting Considerations Flowchart of Installation When Used in LAN 100BASE-TX/10BASE-T System ConnectionsWhen Used in Isdn TerminalInserting Batteries into the Remote Commander InitializationRemoted sensor PCS-1/PCS-1P Standby Mode Function To release the standby modeTurning On Launcher menuWhen the Power was First Turned on after Installation ProtocolArea Code To cancel the setting To go back to the previous wizardSystem Setting LANMODE1 DSB Flowchart of Opening Test Outgoing Procedure of Isdn ControllerStart meeting is displayed, Incoming Procedure of Isdn ScreenOutgoing Procedure of LAN Start meeting is displayed, Incoming Procedure of LAN Section Maintenance Operation procedureSeparation of Components TroubleYES SS-02 Does Power Amber lamp of main unit light? Power is not turned on during automatic incoming. Isdn Power is not turned on during automatic incoming. LAN Is the monitor SS-06 Is the launcher menu No function can be operated using a remote controller Camera on the local side cannot be operated No line is connected. Isdn No line is connected. LAN Is the volume of the monitor TV turned down? SS-12 SS-13 Is video input properly set? Check the terminal of the other end Is the setting of the video signal input correct? Operation log using commercial PC Operation LogPCS-1/PCS-1P PCS-1/PCS-1P PCS-1/PCS-1P PCS-1/PCS-1P Operation log using commercial PC PCS-1/PCS-1P PCS-1/PCS-1P PCS-1/PCS-1P PCS-1/PCS-1P Updating Using Memory Stick Updating of SoftwareService Mode For erasure of an address book and settingFor system reset For command input To stop settingContents of functions For loading of applicationPCS-1/PCS-1P Page Connection via Hub Example of systemOFF Connection via Router OFF Connection via Dhcp OFF Connection via Gatekeeper LAN1 LAN2OFF Connection via Dhcp and Gatekeeper OFF PCS-1/1P Port Number Used During Opposed Connection Specified ValueDuring Use of Internal MCU Function Specified Value Port number at first point Port number at N’th pointSetting of PCS-1 and HUB Table of connection between PCS-1 and CatalystPage Page Sony Corporation
Related manuals
Manual 8 pages 19.36 Kb

PCS-1, PCS-1P specifications

The Sony PCS-1P and PCS-1 are cutting-edge video conferencing solutions designed for businesses seeking high-quality communication tools. Tailored for professional environments, these units facilitate seamless connectivity, encouraging collaboration without geographical barriers.

One of the standout features of the PCS-1P and PCS-1 is their remarkable video quality. Both models support high-definition video, providing sharp, crystal-clear images that enhance the remote communication experience. This clarity is especially beneficial for presentations, allowing participants to see details in charts and graphics with precision. The PCS-1P model specifically offers 720p HD resolution, ensuring that every meeting feels as face-to-face as possible.

In terms of audio, Sony has equipped both the PCS-1P and PCS-1 with advanced audio technologies. These units include high-quality microphones that capture sound from all corners of the room, coupled with noise cancellation features that eliminate background distractions. This results in a clear and engaging communication experience, essential for effective collaboration.

Another significant characteristic of the PCS-1 series is its user-friendly interface. The systems are designed for easy setup and operation, making them accessible even for less tech-savvy users. An intuitive remote control allows users to manage video calls effortlessly, adjusting settings without fumbling through complicated menus.

Connectivity is also a hallmark of the PCS-1P and PCS-1. These devices can connect to a wide range of networks, including IP networks, offering flexibility in how and where users can engage. Additionally, they support both SIP and H.323 protocols, ensuring compatibility with various other video conferencing systems and platforms.

Furthermore, the PCS-1P and PCS-1 models boast built-in record and playback functionalities, allowing users to capture meetings for future reference. This feature is invaluable for businesses that require a record of discussions and decisions made during video conferences.

With their robust feature set, including reliable connectivity, high-definition video and audio quality, and ease of use, Sony's PCS-1P and PCS-1 video conferencing systems stand out as leading solutions for modern enterprises. They not only enhance communication but also promote productivity and collaboration across teams, regardless of their physical location. In a globally connected business environment, these tools represent a strategic asset for any organization aiming to improve its communication efforts.