Heath Zenith PF-4150-SC, PF-4150-PB warranty Testing, Turn on the circuit breaker and light switch

Page 6

TESTING

Turn on the circuit breaker and light switch.

Note: Sensor has a 1 1/2 minute warm up pe- riod before it will detect motion.When first turned on wait 1 1/2 minutes.

Set SENSITIVITY to mid position and ON-TIME to TEST position.

TEST 1 5 10 MIN

LO - M - HI

ON-TIME

SENSITIVITY

Avoid aiming the control at:

Pools of water or objects that change temperature rapidly, such as heating vents and air conditioners. These heat sources could cause false triggering.

Areas where pets or traffic may trigger the control.

Nearby large, light-colored objects reflecting daylight may trigger the shut-off feature. Do not point other lights at the sensor.

150°

6 ft.

(1.8 m)

30ft.

(9.1m)

Maximum Range

Maximum

 

Coverage Angle

The detector is less sensitive to motion di- rectly towards it and more sensitive to across motion.

MotionMotion

Sensor

Least Sensitive

Most Sensitive

Walk through the coverage area noting where you are when the lights turn on. Move the sensor head left or right to change the coverage area.

Note: Grasp the sensor only as shown and turn the entire sensor. Any other method may damage the sensor. Do not force it past the stops.

240°

Sensor Aiming

 

 

Adjustment Angle

SettheSENSITIVITYasneeded.Toomuch sensitivity may increase false triggering.

Set the amount of TIME you want the light to stay on after motion is detected. (1, 5, or 10 minutes).

598-1165-05

Image 6
Contents Operation FeaturesPackage Contents RequirementsAs Shipped InstallationMode Switching Summary RotatedWiring One Motion LightTwo Motion Lights Optional Wiring Wiring DiagramComplete the Installation Top AssemblyOptional Assembly Testing Turn on the circuit breaker and light switchAvoid aiming the control at Specifications Troubleshooting GuideTechnical Service No Service Parts Available for this ProductContenidos del Paquete FuncionamientoCaracterísticas RequisitosInstalacion Resumen de las modalidades del InterruptorADVERTENCIADesconecte la ener- gía en el disyuntor Girada CableadoComo se enviaron Luz de dos movimientosDiagrama de Cableado Conexion AlternaComplete LA Instalacion Ensamble superior del ModeloMontaje Opcional Prueba Prenda el cortacircuitos y el interrup- tor de luzEvite apuntar el control hacia Especificaciones Guia DE Investigacion DE AveriasServicio Técnico No hay piezas de servicio disponibles para este productoContenu de l’emballage FonctionnementCaractéristiques ExigencesRésumé du mode de commutation Câblage Diagramme de câblage Câblage FacultatifComplétez Linstallation Ensemble supérieurEnsemble facultatif Essais Portée maximale Angle de Couverture maximaleFiche Technique Guide DE DépannageService Technique Aucune pièce de rechange n’est disponible pour ce produit