Trane UX1B080A9421A DOWNFLOW/ Horizontal Venting Table Maximum Vent Length, Single Pipe Venting

Page 18

Installer’s Guide

DOWNFLOW/ HORIZONTAL VENTING TABLE

TABLE 11

MAXIMUM VENT LENGTH:

 

DIRECT VENT (2 PIPE SYSTEM) -

 

NONDIRECT VENT (1 PIPE SYSTEM) -

 

MAXIMUM TOTAL EQUIVALENT FEET FOR

MAXIMUM TOTAL EQUIVALENT FEET FOR

 

VENT AND INLET AIR PIPES (See Notes)

VENT PIPE ONLY (See Notes)

 

 

2" PIPE

2-1/2" PIPE

3" PIPE

4" PIPE

2" PIPE

2-1/2" PIPE

3" PIPE

4" PIPE

MODEL

& FITTINGS

& FITTINGS

& FITTINGS

& FITTINGS

& FITTINGS

& FITTINGS

& FITTINGS

& FITTINGS

*DX1B040A9241A

60

80

100

130

50

80

80

130

*DX1B060A9361A

50

80

100

130

50

80

80

130

*DX1B080A9421A

45

80

100

130

40

80

80

130

*DX1C100A9481A

NOT ALLOWED

80

100

130

NOT ALLOWED

80

80

130

*DX1D120A9601A

NOT ALLOWED

15

60

130

NOT ALLOWED

25

70

130

NOTES: * - First letter may be "A" or "T"

1.The INLET AIR of one pipe systems require the installation of a 90° elbow (to prevent dust and debris from falling straight into the furnace) and a 2 foot horizontal or vertical straight pipe section connected before or after the elbow.

2.DO NOT MIX PIPE DIAMETERS IN THE SAME LENGTH OF PIPE OUTSIDE THE FURNACE CABINET (Except adapters at the top of the furnace).

If different inlet and vent pipe sizes are used, the vent pipe must adhere to the maximum length limit shown in the table above (See Note 7 below for exception). The inlet pipe can be of a larger diameter, but never smaller than the vent pipe.

3.MAXIMUM PIPE LENGTHS MUST NOT BE EXCEEDED! THE LENGTH SHOWN IS NOT A COMBINED TOTAL, IT IS THE MAXIMUM LENGTH OF EACH (Vent or Inlet air pipes in two pipe systems).

4.One standard radius 90° elbow is equivalent to 12' of 4" pipe; one SHORT radius 90° elbow is equivalent to 10' of 3" pipe and one LONG radius elbow is equivalent to 6' of 3" pipe. One SHORT/LONG radius 90° elbow is equivalent to 7½' of 2½" pipe, & 5' of 2" pipe. Two 45° elbows equal one 90°elbow.

5.The termination tee or bend must be included in the total number of elbows. If the BAYVENT100 termination kit is used, the equivalent length of pipe is 5 feet. There is zero equivalent length for the BAYVENT200.

6.Pipe adapters are field supplied.

7.4" pipe may be reduced to 3" for termination with BAYAIR30AVENTA or BAYVENT200 without additional length restriction.

UPFLOW FURNACE

 

 

SINGLE PIPE VENTING

Air Inlet

DOWNFLOW

 

 

 

 

 

FURNACE

 

B

 

 

 

A (0-2') or greater

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B (0-2') or greater

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A+B = 2' minimum

 

 

 

 

 

Air Inlet

 

 

 

 

 

 

 

 

 

Vent only

 

A

 

 

 

 

 

 

 

 

to outside

 

 

 

 

 

 

 

 

 

A

 

 

 

 

 

 

 

Vent only

 

 

 

A = 2' minimum

 

 

 

 

 

 

 

 

 

h

 

 

 

 

to outside

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INSIDE

 

 

 

 

 

 

 

 

 

 

CORNER DETAIL

 

 

 

 

 

 

 

 

 

 

 

G

 

 

 

 

 

 

 

 

 

 

V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H

 

 

D

 

 

 

 

 

 

 

 

 

 

 

V

E

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C

 

 

B

 

 

 

 

V

 

 

 

 

 

 

 

 

 

 

B

 

V

FIXED

B

 

 

 

I

 

 

 

 

FIXED

V

 

 

 

L

 

 

CLOSED

 

OPERABLE

 

 

 

 

 

 

 

 

V

CLOSED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OPERABLE

 

 

 

M

 

 

 

 

 

V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F

 

B

V

X

 

V

X

 

 

 

 

 

 

B

J

 

 

 

 

 

 

 

 

A

 

 

K

 

 

 

 

 

B

 

 

 

 

j

 

V

VENT TERMINAL

X

AIR SUPPLY INLET

AREA WHERE TERMINAL IS NOT PERMITTED

 

 

 

 

 

 

 

 

 

 

 

 

 

18

 

 

 

 

 

 

 

 

 

18-CD19D6-32

Image 18
Contents Downflow Upflow UPFLOW/HORIZONTAL DOWNFLOW/HORIZONTAL Safety Section Carbon Monoxide Poisoning HazardInstaller’s Guide Contents Installer’s Guide Outline Drawing Downflow / Horizontal Outline Drawing DX-CHorizontal Installation Downflow InstallationsUpflow Installation Subbase Cross SectionAIR for Combustion and Ventilation Outside AIR is RecommendedUpflow Horizontal Shown Confined Space Duct Connections Return AIR Duct ConnectionFilter Typical Upflow Return AIR Filter INSTALLA- TionsReturn AIR Filters FrontBottom Filter Rack Installation Optional Filter Rack Installation for Bottom ReturnCutout Springs Bottom Panelfilter Installed Rack RailsSide RetainingUnit Return AIR Size Bottom Side Installing the Optional FilterTypical Downflow Furnace Return AIR Filter Installations Cabinet Filter Filter Bracket Width Size LocationGeneral Venting Tion and VentilationPVC Vent Fitting Material Vent Fitting Material PlasticBonding of PVC UPFLOW/ Horizontal Venting Table Maximum Vent Length Equivalent Feet forDOWNFLOW/ Horizontal Venting Table Maximum Vent Length Single Pipe VentingSee Figure Direct Vent Terminal Clearances Horizontal Venting Through Wall Possible Configurations for TWO Pipe Venting SystemsHorizontal Venting BAYVENT200BNoncombustible Material Wall Combustible Material WallBAYAIR30AVENTA Venting Through the RoofAT a Maximum of 3 Intervals TEEDirection of Stainless Steel Fitting BAYAIR30AVENTAType 29-4C Stainless Steel Venting Used Through Chimney That VentsAnother GAS Appliance Installer’s Guide Upflow Vertical Condensate Drain InstructionsVertical Applications Upflow Horizontal 17 UnitsDownflow Vertical Horizontal ApplicationsUpflow Horizontal 21 & 24 Units Downflow HorizontalTwinning Furnaces Furnace SeeElectrical Connections Stage HEATING, 1 Stage CoolingTwinning Connection Diagram GAS Piping Orifice Sizes Combustion and Input CheckFinal Manifold Pressure Settings Fuel PressureHigh Altitude Derate Part Numbers for Replacement Orifices Start UP and AdjustmentReinstallation of the Burner BOX Cover Preliminary InspectionsSequence of Operation Airflow AdjustmentRoom AIR Thermostat Heat Anticipator Adjustment Indoor Blower TimingBurner BOX Temperature Limit Device Abnormal ConditionsInstaller’s Guide Integrated Furnace Control Error Flash Codes Trane

UX1D100A9601A, DX1B060A9361A, UX1D120A9601A, DX1B080A9421A, DX1B040A9241A specifications

The Trane UX1B040A9241A, DX1D120A9601A, UX1D120A9601A, UX1B060A9241A, and DX1C100A9481A are part of Trane's innovative line of HVAC systems, designed to provide efficient heating and cooling for both residential and commercial applications. Each model is equipped with state-of-the-art features and technologies that prioritize energy efficiency, durable performance, and innovative climate control solutions.

The UX1B040A9241A is a top-performing air conditioning unit that incorporates Trane's advanced variable-speed compressor technology. This allows for precise temperature control and consistent comfort while minimizing energy consumption. The system is also known for its quiet operation, making it ideal for residential settings where noise may be a concern.

On the other hand, the DX1D120A9601A model is particularly notable for its high energy efficiency ratings, incorporating a two-stage cooling system that enhances performance even in extreme weather conditions. This unit is engineered with a durable cabinet and a dependable design to stand up to harsh outdoor environments while providing reliable indoor comfort.

The UX1D120A9601A shares many of the same benefits, offering a flexible multi-stage system that can adapt to varying cooling loads. Its compact design allows for easy installation and maintenance, providing owners with versatility in placement and user-friendly servicing options.

The UX1B060A9241A model balances high performance with eco-friendly operation. It features advanced refrigerant technology that is compliant with today's environmental standards while maintaining high-efficiency ratings. This model ensures consistent comfort without sacrificing environmental responsibility.

Meanwhile, the DX1C100A9481A introduces a simplified yet effective approach to heating and cooling. This unit is designed for easy installation and offers user-friendly controls that allow homeowners to effortlessly adjust settings for optimal comfort throughout the year.

Overall, these Trane models come equipped with robust warranties, ensuring that customers have peace of mind with their investment. Their combination of innovative technology, energy efficiency, and reliability establishes Trane as a trusted choice for climate control solutions. Whether for residential or commercial needs, these models deliver quality performance that meets the demands of their users.