Trane DX1C100A9481A manual Type 29-4C Stainless Steel Venting, Used Through Chimney That Vents

Page 24

Installer’s Guide

.

/

TYPE 29-4C STAINLESS STEEL VENTING -

USED THROUGH CHIMNEY THAT VENTS

 

ANOTHER GAS APPLIANCE

 

STAINLESSSTAINLESSSTEEL

 

 

VENTSTEELCAP

 

 

VENT CAP

 

 

(OPTIONAL)

 

SEE CAUTION

6 IN. MIN.

 

 

SUPPORT THE SINGLE WAL

!SEAL BETWEEN FLANGE, PIPE, COUPLING AND METAL PANEL

WITH HI TEMP RTV SILICONE SEALANT

FLUE PIPE

COUPLING

SUPPORT

FLANGE

CEILING

GALVANIZED FIRESTOP SHOULD

BE FABRICATED WITH 3-7/8" DIA.

HOLE FOR SUPPORT FLANGE (12" x 12" PANEL OR 12" DIA MIN.)

CLEARANCE ( 0" ACCEPTABLE FOR PVC VENT PIPE )

( 1" ACCEPTABLE FOR TYPE 29-4C STAINLESS STEEL VENT PIPE )

VENTING THROUGH CEILING

@PVC PLASTIC VENTING - ONLY THROUGH UNUSED CHIMNEY

STAINLESS STEEL

VENTCAP

(OPTIONAL)

SEE CAUTION

6 IN. MIN.

STAINLESS STEEL GAS VENTING AND CENTER IT IN THE CHIMNEY OPENING WI ANGLES AS SHOWN OR ANOTHER EQUIVALENT MANNER.

FLUE PIPE

OUPLING TO SUPPORT PE FROM ANGLES

R OTHER SUITABLE UPPORT METHOD

SUPPORT THE SINGLE WALL FLUE PIPE AND CENTER IT IN THE CHIMNEY OPENING WI ANGLES AS SHOWN O ANOTHER EQUIVALEN MANNER.

COUPLING

AS REQUIRED

NOTE:

HORIZONTAL VENTING

TO VERTICAL VENTING

! CAUTION

Do NOT run vent through chimney for wood burn- ing or oil furnaces or incinerators.

If remaining free area between single wall flue pipe and masonry chimney is to be used for another gas appliance venting area must be sufficient to vent that appliance and that appliance must be con- nected to chimney with separate entry openings.

IMPORTANT

The single wall flue pipe joints must be sealed.

The 90° elbow connection to vertical pipe must be sealed to prevent condensate leakage to base of ma- sonry chimney.

FLUE PIPE

NOTE:

HORIZONTAL VENTING

TO VERTICAL VENTING

! CAUTION

Do NOT run vent through chimney for wood burning or oil furnaces or incinerators or any other gas appliance.

IMPORTANT –

The single wall flue pipe joints must be sealed.

The 90° elbow connection to vertical pipe must be sealed to prevent condensate leakage to base of masonry chimney.

24

18-CD19D6-32

Image 24
Contents Downflow Upflow UPFLOW/HORIZONTAL DOWNFLOW/HORIZONTAL Safety Section Carbon Monoxide Poisoning HazardInstaller’s Guide Contents Installer’s Guide Outline Drawing Downflow / Horizontal Outline Drawing DX-CDownflow Installations Upflow InstallationHorizontal Installation Subbase Cross SectionAIR for Combustion and Ventilation Outside AIR is RecommendedUpflow Horizontal Shown Confined Space Duct Connections Return AIR Duct ConnectionTypical Upflow Return AIR Filter INSTALLA- Tions Return AIR FiltersFilter FrontBottom Filter Rack Installation Optional Filter Rack Installation for Bottom ReturnSprings Bottom Panelfilter Installed Rack Rails SideCutout RetainingInstalling the Optional Filter Typical Downflow Furnace Return AIR Filter InstallationsUnit Return AIR Size Bottom Side Cabinet Filter Filter Bracket Width Size LocationGeneral Venting Tion and VentilationPVC Vent Fitting Material Vent Fitting Material PlasticBonding of PVC UPFLOW/ Horizontal Venting Table Maximum Vent Length Equivalent Feet forDOWNFLOW/ Horizontal Venting Table Maximum Vent Length Single Pipe VentingSee Figure Direct Vent Terminal Clearances Possible Configurations for TWO Pipe Venting Systems Horizontal VentingHorizontal Venting Through Wall BAYVENT200BCombustible Material Wall BAYAIR30AVENTANoncombustible Material Wall Venting Through the RoofAT a Maximum of 3 Intervals TEEDirection of Stainless Steel Fitting BAYAIR30AVENTAType 29-4C Stainless Steel Venting Used Through Chimney That VentsAnother GAS Appliance Installer’s Guide Condensate Drain Instructions Vertical ApplicationsUpflow Vertical Upflow Horizontal 17 UnitsHorizontal Applications Upflow Horizontal 21 & 24 UnitsDownflow Vertical Downflow HorizontalTwinning Furnaces Furnace SeeElectrical Connections Stage HEATING, 1 Stage CoolingTwinning Connection Diagram GAS Piping Orifice Sizes Combustion and Input CheckFinal Manifold Pressure Settings Fuel PressureHigh Altitude Derate Start UP and Adjustment Reinstallation of the Burner BOX CoverPart Numbers for Replacement Orifices Preliminary InspectionsAirflow Adjustment Room AIR Thermostat Heat Anticipator AdjustmentSequence of Operation Indoor Blower TimingBurner BOX Temperature Limit Device Abnormal ConditionsInstaller’s Guide Integrated Furnace Control Error Flash Codes Trane

UX1D100A9601A, DX1B060A9361A, UX1D120A9601A, DX1B080A9421A, DX1B040A9241A specifications

The Trane UX1B040A9241A, DX1D120A9601A, UX1D120A9601A, UX1B060A9241A, and DX1C100A9481A are part of Trane's innovative line of HVAC systems, designed to provide efficient heating and cooling for both residential and commercial applications. Each model is equipped with state-of-the-art features and technologies that prioritize energy efficiency, durable performance, and innovative climate control solutions.

The UX1B040A9241A is a top-performing air conditioning unit that incorporates Trane's advanced variable-speed compressor technology. This allows for precise temperature control and consistent comfort while minimizing energy consumption. The system is also known for its quiet operation, making it ideal for residential settings where noise may be a concern.

On the other hand, the DX1D120A9601A model is particularly notable for its high energy efficiency ratings, incorporating a two-stage cooling system that enhances performance even in extreme weather conditions. This unit is engineered with a durable cabinet and a dependable design to stand up to harsh outdoor environments while providing reliable indoor comfort.

The UX1D120A9601A shares many of the same benefits, offering a flexible multi-stage system that can adapt to varying cooling loads. Its compact design allows for easy installation and maintenance, providing owners with versatility in placement and user-friendly servicing options.

The UX1B060A9241A model balances high performance with eco-friendly operation. It features advanced refrigerant technology that is compliant with today's environmental standards while maintaining high-efficiency ratings. This model ensures consistent comfort without sacrificing environmental responsibility.

Meanwhile, the DX1C100A9481A introduces a simplified yet effective approach to heating and cooling. This unit is designed for easy installation and offers user-friendly controls that allow homeowners to effortlessly adjust settings for optimal comfort throughout the year.

Overall, these Trane models come equipped with robust warranties, ensuring that customers have peace of mind with their investment. Their combination of innovative technology, energy efficiency, and reliability establishes Trane as a trusted choice for climate control solutions. Whether for residential or commercial needs, these models deliver quality performance that meets the demands of their users.