Trane DX1D120A9601A, UX1C100A9481A manual Direction of Stainless Steel Fitting, BAYAIR30AVENTA

Page 23

DOWNWARD VENTING

b

Furnace may be in vertical or horizontal configuration.

DOWNWARD VENT

LENGTH IS LIMITED

TO A MAXIMUM OF 15

EQUIVALENT FEET.

40 Inch

Upflow or Downflow Furnace

Slope 1/4" per ft.

Slope 1/4" per ft.

6" Min.

All horizontal pipes must be supported

at a maximum of 3 foot intervals

NOTES:

Installer’s Guide

NOTE:

Both venting methods shown in Figure 40 & 42 must also have the combustion air inlet installed - meeting dimension requirements of Figure 36.

n

A)Condensate trap for vent pipe must be a minimum of 6 inches in height.

B)Condensate trap for vent and inlet pipe must be connected into a condensate drain pump; an open or vented drain; or it can be connected to the outlet hose of the furnace's condensate trap. Outdoor draining of the furnace and coil condensate is per- missible if allowed by local codes. Caution should be taken to prevent drains from freezing or causing slippery conditions that could lead to personal in- jury. Excessive draining of condensate may cause saturated ground conditions that may result in damage to plants.

C)The condensate trap should be primed at initial start up prior to heating season operation.

VENTING ROUTED THROUGH A MASONRY CHIMNEY VENT FITTING MATERIAL – STAINLESS STEEL

Gas and liquid tight single wall metal vent fitting, de- signed for resistance to corrosive flue condensate such as Type 29-4C MUST be used throughout.

m

MAINTAIN 12 IN.

(18 IN. FOR CANADA) MINIMUM CLEARANCE ABOVE HIGHEST ANTICIPATED SNOW LEVEL. MAXIMUM OF 24 IN. ABOVE ROOF.

BAYAIR30AVENTA

VENT

COMBUSTION

AIR

These fittings and fitting accessories are to be supplied locally.

DIRECTION OF STAINLESS STEEL FITTING

All stainless steel fitting must be installed with male end towards the furnace.

All horizontal stainless steel sections must be posi- tioned with the seam on top.

All long horizontal sections must be supported to pre-

, VENT

REMOVE RIBS FROM CAP

COMBUSTION

AIR

ROOF FLASHING BOOT

(FIELD SUPPLIED)

MAINTAIN 12 IN.

(18 IN. FOR CANADA) MINIMUM CLEARANCE ABOVE HIGHEST ANTICIPATED SNOW LEVEL. MAXIMUM OF 24 IN. ABOVE ROOF

vent sagging.

All pipe joints must be fastened and sealed to prevent escape of combustion products into the building.

SUPPORT

(FIELD SUPPLIED)

ELBOW

(FIELD SUPPLIED)

VENT

 

 

 

 

 

 

COMBUSTION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AIR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

18-CD19D6-32

23

Image 23
Contents Downflow Upflow UPFLOW/HORIZONTAL DOWNFLOW/HORIZONTAL Carbon Monoxide Poisoning Hazard Safety SectionInstaller’s Guide Contents Installer’s Guide Outline Drawing DX-C Downflow / Horizontal Outline DrawingSubbase Cross Section Downflow InstallationsUpflow Installation Horizontal InstallationUpflow Horizontal Shown AIR for Combustion and VentilationOutside AIR is Recommended Confined Space Return AIR Duct Connection Duct ConnectionsFront Typical Upflow Return AIR Filter INSTALLA- TionsReturn AIR Filters FilterOptional Filter Rack Installation for Bottom Return Bottom Filter Rack InstallationRetaining Springs Bottom Panelfilter Installed Rack RailsSide CutoutCabinet Filter Filter Bracket Width Size Location Installing the Optional FilterTypical Downflow Furnace Return AIR Filter Installations Unit Return AIR Size Bottom SideTion and Ventilation General VentingBonding of PVC PVC Vent Fitting MaterialVent Fitting Material Plastic Equivalent Feet for UPFLOW/ Horizontal Venting Table Maximum Vent LengthSingle Pipe Venting DOWNFLOW/ Horizontal Venting Table Maximum Vent LengthSee Figure Direct Vent Terminal Clearances BAYVENT200B Possible Configurations for TWO Pipe Venting SystemsHorizontal Venting Horizontal Venting Through WallVenting Through the Roof Combustible Material WallBAYAIR30AVENTA Noncombustible Material WallTEE AT a Maximum of 3 IntervalsBAYAIR30AVENTA Direction of Stainless Steel FittingAnother GAS Appliance Type 29-4C Stainless Steel VentingUsed Through Chimney That Vents Installer’s Guide Upflow Horizontal 17 Units Condensate Drain InstructionsVertical Applications Upflow VerticalDownflow Horizontal Horizontal ApplicationsUpflow Horizontal 21 & 24 Units Downflow VerticalFurnace See Twinning FurnacesStage HEATING, 1 Stage Cooling Electrical ConnectionsTwinning Connection Diagram GAS Piping Combustion and Input Check Orifice SizesFuel Pressure Final Manifold Pressure SettingsHigh Altitude Derate Preliminary Inspections Start UP and AdjustmentReinstallation of the Burner BOX Cover Part Numbers for Replacement OrificesIndoor Blower Timing Airflow AdjustmentRoom AIR Thermostat Heat Anticipator Adjustment Sequence of OperationAbnormal Conditions Burner BOX Temperature Limit DeviceInstaller’s Guide Integrated Furnace Control Error Flash Codes Trane

UX1D100A9601A, DX1B060A9361A, UX1D120A9601A, DX1B080A9421A, DX1B040A9241A specifications

The Trane UX1B040A9241A, DX1D120A9601A, UX1D120A9601A, UX1B060A9241A, and DX1C100A9481A are part of Trane's innovative line of HVAC systems, designed to provide efficient heating and cooling for both residential and commercial applications. Each model is equipped with state-of-the-art features and technologies that prioritize energy efficiency, durable performance, and innovative climate control solutions.

The UX1B040A9241A is a top-performing air conditioning unit that incorporates Trane's advanced variable-speed compressor technology. This allows for precise temperature control and consistent comfort while minimizing energy consumption. The system is also known for its quiet operation, making it ideal for residential settings where noise may be a concern.

On the other hand, the DX1D120A9601A model is particularly notable for its high energy efficiency ratings, incorporating a two-stage cooling system that enhances performance even in extreme weather conditions. This unit is engineered with a durable cabinet and a dependable design to stand up to harsh outdoor environments while providing reliable indoor comfort.

The UX1D120A9601A shares many of the same benefits, offering a flexible multi-stage system that can adapt to varying cooling loads. Its compact design allows for easy installation and maintenance, providing owners with versatility in placement and user-friendly servicing options.

The UX1B060A9241A model balances high performance with eco-friendly operation. It features advanced refrigerant technology that is compliant with today's environmental standards while maintaining high-efficiency ratings. This model ensures consistent comfort without sacrificing environmental responsibility.

Meanwhile, the DX1C100A9481A introduces a simplified yet effective approach to heating and cooling. This unit is designed for easy installation and offers user-friendly controls that allow homeowners to effortlessly adjust settings for optimal comfort throughout the year.

Overall, these Trane models come equipped with robust warranties, ensuring that customers have peace of mind with their investment. Their combination of innovative technology, energy efficiency, and reliability establishes Trane as a trusted choice for climate control solutions. Whether for residential or commercial needs, these models deliver quality performance that meets the demands of their users.