General

A well water application involves an open loop water supply. The water is drawn from an open well or pond into the unit. A straining device is required with this application.

Similar to the closed loop design, an open water supply usually remains at a constant temperature year round utilizing maximum efficiency in unit design.

See Figure 11 for open well water installation.

Well Water

Application

￿￿Ball valves should be installed in the supply and return lines for unit isolation and unit water flow rate balancing (if auto- matic flow device is not selected). This connection, along with hoses, are also rec- ommended for backflushing and chemical cleaning of the evaporator and the condenser.

￿￿Flexible hoses may be used to connect the water supply and return lines to the water inlets and outlets. These hoses reduce possible vibration between the unit and the rigid system.

Note: Hoses and or pipes should be braided stainless steel, and sized suitable for the system’s water pressure and flow rate.

￿￿Load side connections are used to supply the terminal device.

￿￿The sound attenuation pad should be slightly oversized for the unit. This field supplied product is recommended for sound absorption of unit.

￿￿The low voltage control con- nection provided on the unit is large enough for attaching con- duit.

￿￿The expansion tank should be sized to maintain pressure on the system.

￿￿The line voltage disconnect should be installed for branch circuit protection. The unit is supplied with an opening for attaching conduit.

￿￿The water regulating valve assembly is used to maintain refrigerant pressure in refriger- ant circuit as the entering water temperature varies or is cooler than ideal.

￿￿Schrader connections are factory installed for ease of attaching the water regulating valve assembly.

16

Image 16
Contents WSHP-DS-6 March Water Source Heat Pump Water-to-Water Model WpwdIntroduction Table of Contents Features General Benefits Features Controls Benefits Desuperheater Option Features Heat Recovery BenefitsCirculating Pump Digit 8 Voltage / Hertz / Phase Model Number DescriptionGeneral Data Table G-1 Physical Data EnglishApplication Considerations Closed Loop SystemOpen Loop System Cooling Tower/Boiler SystemApplication Source Side Considerations Load Side Source vs. LoadGeothermal Integrated System Application Closed Loop Considerations GeothermalTypical Benefits Application Fresh Air Considerations Ventilation Water-to-Water Fresh Air VentilationApplication Fresh Air Considerations Ventilation Mechanical Application Central Considerations Pumping System Central Pump ApplicationApplication Well Water Considerations Systems Well Water ApplicationApplication Distributed Considerations Pumping System Earth Coupled ApplicationElectrical Data Table E-1 Electrical Data

WSHP-DS-6 specifications

The Trane WSHP-DS-6, or Water Source Heat Pump - Design Series 6, is a highly efficient and versatile solution designed to meet the complex heating and cooling needs of commercial buildings. With a firm reputation for reliability and performance, the WSHP-DS-6 integrates advanced technologies to optimize energy consumption and enhance climate control.

One of the standout features of the WSHP-DS-6 is its exceptional efficiency ratings. The unit boasts a high Coefficient of Performance (COP) and Energy Efficiency Ratio (EER), ensuring that it delivers cost-effective heating and cooling while minimizing energy usage. This not only lowers operational costs but also contributes to reduced environmental impact.

The heat pump is equipped with a hermetically sealed scroll compressor, known for its durability and quiet operation. This technology allows for smooth operation under a variety of conditions, making the WSHP-DS-6 suitable for different environments. The compressor, combined with a robust heat exchanger, ensures optimal heat transfer, resulting in enhanced overall system performance.

Another notable characteristic of the WSHP-DS-6 is its compact design, which facilitates easy installation in a variety of settings, including tight spaces often found in urban environments. Additionally, the unit comes with advanced controls that allow for precise temperature management, ensuring the indoor environment remains comfortable year-round.

The WSHP-DS-6 also supports water heating capabilities, providing hot water on demand. This flexibility makes it a cost-effective solution for facilities that require both space heating and hot water supply, such as hotels, schools, and healthcare facilities.

Moreover, the unit features integrated zone control options, which enable the customization of heating and cooling for different areas within a building. By allowing targeted climate control, the WSHP-DS-6 enhances occupant comfort while further improving overall energy efficiency.

In terms of sustainability, the WSHP-DS-6 is designed to work effectively with environmentally friendly refrigerants, aligning with current regulations and promoting eco-friendly practices. This commitment to sustainability, combined with superior performance features, makes the Trane WSHP-DS-6 a top choice for building managers seeking reliable and efficient climate control solutions.

Overall, the Trane WSHP-DS-6 represents a perfect blend of technology, efficiency, and adaptability, making it an excellent investment for commercial property owners focused on sustainable building management.