Application

Considerations

Closed Loop System

Closed loop systems (both ground source and surface water) provide heat rejection and heat addition to maintain proper water source temperatures.

Operating and maintenace cost are low because an auxillary fossil fuel boiler and cooling tower are not required to maintain the loop temperature. The technology has advanced to the point where many electric utilities and rural electric cooperatives are offering incentives for the installation of geothermal systems. These incentives are offered because of savings to the utilities due to reduced peak loads that flatten out the system demand curve over time.

For ground source geothermal systems, (See Figure 5), when building cooling

requirements cause loop water temperatures to rise, heat is dissapated into the cooler earth through buried polyethylene pipe heat exchangers. If reversed, heating demands cause the loop temperature to fall, enabling the earth to add heat to meet load requirements.

Where local building codes require water retention ponds for short term storage of surface run-off, a ground source surface water system, (See Figure 6), can be very cost effective. This system has all the advantages as the geothermal system in cooling dominated structures.

Another benefit of the ground source system is that it is environmentally friendly. The loop is made of chemically inert, non-polluting polyethylene pipe. The heat pumps use HCFC-22 refrigerant, which has a lower ozone depletion potential than CFC-12. Because the closed loop system does not require a heat adder, there are no CO2 emissions. Less electric power consumed reduces secondary emissions from the power plant. Therefore, the system offers advantages not seen by other central furnace or heat pump systems.

Figure 5: Ground source geothermal system

Figure 6: Ground source surface water system

9

Image 9
Contents March Water Source Heat Pump Water-to-Water Model Wpwd WSHP-DS-6Introduction Table of Contents Features General Benefits Features Controls Benefits Features Heat Recovery Benefits Desuperheater OptionCirculating Pump Model Number Description Digit 8 Voltage / Hertz / PhaseTable G-1 Physical Data English General DataClosed Loop System Application ConsiderationsCooling Tower/Boiler System Open Loop SystemSource vs. Load Application Source Side Considerations Load SideApplication Closed Loop Considerations Geothermal Geothermal Integrated SystemTypical Benefits Water-to-Water Fresh Air Ventilation Application Fresh Air Considerations VentilationApplication Fresh Air Considerations Ventilation Mechanical Central Pump Application Application Central Considerations Pumping SystemWell Water Application Application Well Water Considerations SystemsEarth Coupled Application Application Distributed Considerations Pumping SystemTable E-1 Electrical Data Electrical Data

WSHP-DS-6 specifications

The Trane WSHP-DS-6, or Water Source Heat Pump - Design Series 6, is a highly efficient and versatile solution designed to meet the complex heating and cooling needs of commercial buildings. With a firm reputation for reliability and performance, the WSHP-DS-6 integrates advanced technologies to optimize energy consumption and enhance climate control.

One of the standout features of the WSHP-DS-6 is its exceptional efficiency ratings. The unit boasts a high Coefficient of Performance (COP) and Energy Efficiency Ratio (EER), ensuring that it delivers cost-effective heating and cooling while minimizing energy usage. This not only lowers operational costs but also contributes to reduced environmental impact.

The heat pump is equipped with a hermetically sealed scroll compressor, known for its durability and quiet operation. This technology allows for smooth operation under a variety of conditions, making the WSHP-DS-6 suitable for different environments. The compressor, combined with a robust heat exchanger, ensures optimal heat transfer, resulting in enhanced overall system performance.

Another notable characteristic of the WSHP-DS-6 is its compact design, which facilitates easy installation in a variety of settings, including tight spaces often found in urban environments. Additionally, the unit comes with advanced controls that allow for precise temperature management, ensuring the indoor environment remains comfortable year-round.

The WSHP-DS-6 also supports water heating capabilities, providing hot water on demand. This flexibility makes it a cost-effective solution for facilities that require both space heating and hot water supply, such as hotels, schools, and healthcare facilities.

Moreover, the unit features integrated zone control options, which enable the customization of heating and cooling for different areas within a building. By allowing targeted climate control, the WSHP-DS-6 enhances occupant comfort while further improving overall energy efficiency.

In terms of sustainability, the WSHP-DS-6 is designed to work effectively with environmentally friendly refrigerants, aligning with current regulations and promoting eco-friendly practices. This commitment to sustainability, combined with superior performance features, makes the Trane WSHP-DS-6 a top choice for building managers seeking reliable and efficient climate control solutions.