MAKING ADJUSTMENTS AND FITTING SPARES
CAUTION: THE FOLLOWING SECTION IS FOR USE BY QUALIFIED SERVICE PERSONNEL ONLY. TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE THE TOP FASCIA TO PERFORM ANY SERVICING OR OTHER TASKS, UNLESS YOU ARE QUALIFIED TO DO SO.
BEFORE REMOVING THE TOP FASCIA ENSURE THE UNIT IS
DISCONNECTED FROM THE MAINS SUPPLY.
ONLY REMOVE THE ALLEN SCREWS INDICATED ON THE DIAGRAM OPPOSITE.
WARNING: DO NOT
It is necessary to remove the top panel fascia in order to carry out one or more of the following tasks:
Setting the
Changing the orientation of the Phono/Line switches.
Replacing any of the four linear faders.
Removing the Sampler section
To remove the top panel fascia proceed as follows:
Pull off all the fader and pot knobs.
Undo the 6 retaining Allen screws using a 2mm Allen key. These are located down the left and right hand edges of the fascia. The fascia can now be lifted clear of the subframe underneath. Take care not to bend the panel.
The diagram opposite shows a view of the mixer (1601S) without the top fascia fitted.
Setting The Pre-trim Pads
There are 2 pads on each of the 2 input channels. The
Changing The Orientation Of The Phono/Line Switches
Using a 2mm Allen key undo and remove the 3 Allen screws around the edge of the circular switch mounting plate. The switch plate can now be rotated in
Replacing The Faders
Using a 2mm Allen key undo and remove the 3 Allen screws (the
Replaceable Spares Part Numbers
RS2331 - Urei 1601/S Sampler Spares Assembly
RS2332 - Urei 1601/S Fader Spares Assembly
RS2333 - Urei 1601/S Phono/ Line Switch Spares Assembly
RS2334 - Urei 1601/S
RS2335 - Urei 1601/S EQ L&R Spares Assembly
14