Baldor MN754 manual ‐1 Characteristics, ‐2 Signal Resolution, High Resolution Outputs

Page 10

Table 2‐1 Characteristics

High

Number of Inputs

Two

Resolution

 

 

Input Signal Levels

+5VDC, +10VDC, 0-20 mA or

Inputs

 

4-20mA

 

 

 

 

 

 

Maximum Digital Resolution

16 bits

High

Number of Outputs

Two

Resolution

 

 

Output Signal Levels

0-5VDC, +5VDC, 0-10VDC,

Outputs

 

+10VDC, 0-20 mA or 4-20mA

 

 

 

 

Maximum Digital Resolution

16 bits

Table 2‐2 Signal Resolution

Input Signal

Signal Type

 

Digital Resolution

Analog Resolution

 

 

High Resolution Inputs

 

±10VDC

Voltage

 

16 Bits (65636 Parts)

305 mVDC

 

 

 

 

(0.000305 VDC)

 

 

 

 

 

±5VDC

Voltage

 

15 Bits (65636 Parts)

305 mVDC

 

 

 

 

(0.000305 VDC)

 

 

 

 

 

4‐20mA

Current

 

15 Bits (65636 Parts)

0.061 mA

0-20 mA

 

 

 

(0.000061 AMP)

 

 

 

 

 

High Resolution Outputs

±10VDC

Voltage

16 Bits (65636 Parts)

305 mVDC

 

 

 

(0.000305 VDC)

 

 

 

 

0‐10VDC

Voltage

15 Bits (65636 Parts)

305 mVDC

 

 

 

(0.000305 VDC)

 

 

 

 

±5VDC

Voltage

15 Bits (65636 Parts)

305 mVDC

 

 

 

(0.000305 VDC)

 

 

 

 

0‐5VDC

Voltage

14 Bits (65636 Parts)

305 mVDC

 

 

 

(0.000305 VDC)

 

 

 

 

4‐20mA

Current

15 Bits (65636 Parts)

0.061 mA

0-20 mA

 

 

(0.000061 AMP)

 

 

 

 

2‐2 Description

Image 10
Contents MN754 Page Table of Contents Ii Table of Contents Introduction Section General Information‐1 VS1 Expansion Boards Board Name Catalog No Limited Warranty Safety Notice ‐4 General Information Installation Considerations Section Expansion Board DescriptionDigital Resolution Analog Resolution High Resolution Inputs ‐1 Characteristics‐2 Signal Resolution High Resolution OutputsBoard Installation Section InstallationReceiving & Inspection ‐1 Expansion Board Slot Locations Jumper Definitions Description‐3 High Resolution Input Connections Overview Section Software SetupEXBHH005 HI RES Expansion Board Hi RES Parameters Parameter Adjustable Range Factory User SettingOpt1 Ana In1 Opt1 Ana In2 Opt2 Ana In1 Opt2 Ana In2 OP2 ANA IN1 Parameter Adjustable Range Factory User Set‐ Ting OP1 OP2 ANAOUT1 OP2 Level 2, Miscellaneous Block Installed Option Boards Section TroubleshootingDiagnostic Screen Display Comments‐2 Troubleshooting Baldor District Offices World Headquarters Box 2400 Fort Smith, AR