Baldor MN754 manual OP2 ANA IN1

Page 17

Hi RES Parameters Continued

Level 1, Input Setup Block Continued

Parameter

P#

Adjustable Range

Factory

User Setting

OP2 ANA IN1

1463

0-None, 1-(-10V to+10V),

1

 

TYPE

 

2-(-5V to+5V),

 

 

 

 

3-(4to20mA), 4-(0to20mA)

 

 

 

 

 

 

 

OP2 ANA IN1

1464

0-OFF, 1-ON

0

 

Invert

 

 

 

 

 

 

 

 

 

OP2 ANA IN1

1465

0.0% TO 300.0%

100.0

 

Gain

 

 

 

 

 

 

 

 

 

OP2 ANA IN1

1466

-100.0% TO 100.0%

0.0

 

Offset

 

 

 

 

 

 

 

 

 

OP2 ANA IN1

1467

0.0% TO 75.0%

0.0

 

Deadband

 

 

 

 

 

 

 

 

 

OP2 ANA IN1

1468

0 (No Filter) TO 6 (Max Filter)

0

 

Filter

 

 

 

 

 

 

 

 

 

OP2 ANA IN2

1469

0-None, 1-(-10V to+10V),

1

 

TYPE

 

2-(-5V to+5V),

 

 

 

 

3-(4to20mA), 4-(0to20mA)

 

 

OP2 ANA IN2

1470

0-OFF, 1-ON

0

 

Invert

 

 

 

 

 

 

 

 

 

OP2 ANA IN2

1471

0.0% TO 300.0%

100.0

 

Gain

 

 

 

 

 

 

 

 

 

OP2 ANA IN2

1472

-100.0% TO 100.0%

0.0

 

Offset

 

 

 

 

 

 

 

 

 

OP2 ANA IN1

1473

0.0% TO 75.0%

0.0

 

Deadband

 

 

 

 

 

 

 

 

 

OP2 ANA IN1

1474

0 (No Filter) TO 6 (Max Filter)

0

 

Filter

 

 

 

 

OP2 parameter selections (P#1463 to 1474) are available if the expansion board is installed in Slot2 of the Control.

Setup 4‐3

Image 17
Contents MN754 Page Table of Contents Ii Table of Contents ‐1 VS1 Expansion Boards Board Name Catalog No Section General InformationIntroduction Limited Warranty Safety Notice ‐4 General Information Section Expansion Board Description Installation Considerations‐2 Signal Resolution ‐1 CharacteristicsDigital Resolution Analog Resolution High Resolution Inputs High Resolution OutputsReceiving & Inspection Section InstallationBoard Installation ‐1 Expansion Board Slot Locations Description Jumper Definitions‐3 High Resolution Input Connections EXBHH005 HI RES Expansion Board Section Software SetupOverview Opt1 Ana In1 Opt1 Ana In2 Opt2 Ana In1 Opt2 Ana In2 Parameter Adjustable Range Factory User SettingHi RES Parameters OP2 ANA IN1 Parameter Adjustable Range Factory User Set‐ Ting OP1 OP2 ANAOUT1 OP2 Level 2, Miscellaneous Block Diagnostic Screen Section TroubleshootingInstalled Option Boards Display Comments‐2 Troubleshooting Baldor District Offices World Headquarters Box 2400 Fort Smith, AR