The audio outputs on the AV-P2 Output Module can be connected to balanced or unbalanced devices via the Euroblock jacks.

Wiring a Euroblock

Euroblock connectors provide an easy, solder-free way of making audio connections between the AV-P2 and other audio components. Only a small flat-blade screw driver is required to make connections. For extra strength, you can add solder to each bare wire on an audio cable to stop the wire strands from unwinding (called “tinning”).

AUDIO OUTPUT

LEFT RIGHT AV-P2

+ –

+ –

AV-P2 left/right Euroblock audio outputs

Connecting to a Balanced Device

To connect the AV-P2 Euroblock audio output to a device that can accept a balanced line-level input:

1.Strip the insulating jacket of the cable back about .75 inch (18 mm) to reveal the individual hot, cold, and ground wires within.

2.Remove a small amount of each individual wire’s insulation (approximately .25 inch, 6 mm).

3.On the 5.0 mm Euroblock male plug, use a small screw driver to loosen and open the sockets that will receive the individual wires.

4.Insert the individual hot (+), cold (-), and ground wires into the matching sockets on the Euroblock plug.

5.Tighten the screws on the wire sockets to secure the individual wires.

6.Plug the completed Euroblock plug into the desired output channel on the AV-P2.

7.Connect the AV-P2 to your audio device.

The Euroblock plug, showing the screws that hold the individual wires in place (left-to-right), hot (+), cold (-), and ground

Connecting to an Unbalanced Device

The AV-P2 audio outputs can be connected to unbalanced audio devices; connections can use single-conductor or two-conductor shielded cable.

Single-conductor shielded cable

To connect the AV-P2 audio output to an unbalanced line-level device using single-conductor shielded cable:

1.Strip the insulating jacket of the cable back about .75 inch (18 mm) to reveal the individual hot and ground wires within.

2.Remove a small amount of each individual wire’s insulation (approximately .25 inch, 6 mm).

3.On the Euroblock plug, use a small screw driver to loosen and open the sockets that will receive the individual wires.

4.Insert the audio cable’s hot (+) wire into the matching socket on the Euroblock plug.

5.Insert the audio cable’s ground wire into the matching socket on the Euroblock plug. The cold (-) socket on the Euroblock remains unused in this configuration.

6.Tighten the screws on the wire sockets to secure the individual wires.

7.Plug the completed Euroblock plug into the desired output channel on the AV-P2.

8.Connect the completed cable to your audio device.

Two-conductor shielded cable

To connect the AV-P2 audio output to an unbalanced line-level device using two-conductor shielded cable:

14

15

Image 15
Contents AV-P2 Trademarks CertificationsImportant Safety Instructions Aviom, Inc. Limited Warranty Warranty InformationTable of Contents Page Welcome Package ContentsRear Panel Components Front Panel ComponentsCompatibility About A-Net Pro16 Series SystemsCables Used With A-Net Devices Cat-5e Cable LengthsSystem Bridge Extending Cable Lengths Cleaning and MaintenanceAC Line Conditioning Mounting the AV-P2AV-P2 Front Panel Panel DescriptionsNet Connections Power ConnectorAV-P2 Rear Panel Audio OutputsConnecting to an Unbalanced Device Connecting AudioWiring a Euroblock Connecting to a Balanced DeviceSetting Output Levels DIP Switch Setting DIP Switch Settings TableParallel A-Net Routing Using an A-Net DistributorNet Connections Series Connection of A-Net DevicesDigital Splits Audio NetworksChannel Systems Extending A-Net Cable RunsNet Expansion To headphonesTo configure a 32 x 0 system Channel ExamplesChannels Send by Zero Channels Return To configure a 16 x 16 system Adding More Audio OutputsChannels Send by 16 Channels Return To create an expanded network Expanding a Network with an A-Net DistributorDimensions SpecificationsBlock Diagram Fax this form to Aviom at +1 Aviom Warranty RegistrationIndex Specifications  Split