TrueAir TRCB-82 / TRCB-52 manual Locating, Installation of Legs and Castors, Step Leveling Castors

Page 7

True Food Service Equipment, Inc.

INSTALLATION / OPERATION INSTRUCTIONS

LOCATING

Step 2

A.Place packing material behind cabinet as a cushion. Carefully lay the unit on its back to remove skid.

When lifting unit remember to

leave the cabinet upright for 24 hours before

plugging into power source.

B.Remove skid by unscrewing all base rail anchor brackets. Place skid to the side.

C.Carefully lift cabinet upright.

Removing skid from bottom of cabinet.

INSTALLATION OF LEGS AND CASTORS

Important Safeguard for installation of leg/castor (Images 1 & 2 demonstrate procedure)

Step 3

Leveling Castors

Four sets of shims have been provided in warranty packet for leveling castored units positioned on uneven floors. Shims must be positioned between cabinet and castor mounting plate.

(See image 1 below).

If the cabinet is not level prop up one end of the cabinet between castors with a 6” block.

(See image 2)

NOTE:

Do not push block more than 5” under cabinet.

Loosen castor bolts with an adjustable wrench enough to slide shims between the castor mounting plate and cabinet bottom.

Install the desired number of shims (in pairs as shown in image 1), making sure the slots in the shim are in contact with the castor mounting bolts.

Tighten and secure the shims and castor(s). Remove 6” block and check to determine if cabinet is level. Repeat process until cabinet is level.

Ensure that the drain hose or hoses are positioned in the pan.

Top View

Left Shim

In Position

Leveling Shims

35° F°

6”

(Image 2.)

Leveling Shims

Side View

Snug

Fit

Here

 

Castor

Mounting

Plate

Castor

(Image 1.)

5

www.truemfg.com

5

Image 7
Contents Trcb Models Chef Base Equipment True Food Service Equipment, Inc Safety Precautions Refrigerant Disposal Proper Disposal of the RefrigeratorUSE of Extension Cords Before You Throw Away Your Old Refrigerator or FreezerNorth America Use Only HOW to Connect ElectricityStep Installation / Operation Instructions OwnershipRequired Tools UncratingLocating Installation of Legs and CastorsStep Leveling Castors Electrical Instructions LevelingConductors and Circuits Recommendation StartupRequired Tools MAINTENANCE, Care & Cleaning Cleaning the Condenser CoilDisconnect the electrical power to the unit Important Warranty InformationDanfoss Temperature Control High Altitude Adjustment Only Temperature Control Adjustment for High Altitude onlyStainless Steel Equipment Care and Cleaning Stainless Steel Equipment Care and Cleaning Warranty Information A & Canada only