Monessen Hearth ODGR500, ODGR400 manual Optional Weather Enclosure, Optional Stainless Steel Hood

Page 12

ODGR Series Outdoor Gas Fireplace

Optional Weather Enclosure

An optional weather enclosure is available to protect the burner when not in use.

CAUTION: Do not use the weather enclosure if the unit has glass doors installed.

Installation Instructions

1.Turn the unit OFF and allow to cool.

2.Grab the weather enclosure by the handle(s).

3.Slide the top of the weather enclosure up between the back of the surround top and the screen rail. (Fig. 19)

4.Push the bottom of the weather enclosure into the firebox just enough to clear the valve access cover and set down. (Fig. 20)

 

Surround Top

Screen Rail

Weather Enclosure

 

KT457

Fig. 19 Place top of weather enclosure between surround top and screen rail.

Screen

Hearth Brick

Valve Access Cover

KT458

Fig. 20 Push bottom of weather enclosure into firebox.

Optional Stainless Steel Hood

An optional stainless steel hood is available for both the ODGR400 and ODGR500.

NOTE: The stainless steel hood may NOT be used when the optional glass doors are

installed. Installation Instructions:

1.Turn the unit off and allow to cool.

2.Place the hood so the 2B\," (67 mm) slot clears the sensor plate located under the fireplace opening on the top left side. (Fig. 21)

3.Secure the hood to the unit using the three (3) slots in the hood and the pilot holes in the unit with the stainless steel sheet metal screws provided. (Fig. 21)

4.Align the sides of the hood so the pilot holes on the right and left sides of the unit are exposed through the slots on the ends of the hood. Secure using the remaining stainless steel sheet metal screws. (Fig. 21)

 

Stainless

 

Steel Hood

 

Stainless

 

Steel Sheet

 

Metal Screws

 

(5)

 

Sensor Plate Slot

 

FP1635

Fig. 21

Secure stainless steel hood with five (5) sheet metal

screws.

 

12

92D0001

Image 12
Contents Outdoor Gas Fireplace Models ODGR400, ODGR500 Table of Contents General Information Enclosures for LP-Gas Supply SystemsDescription Fireplace Dimensions Screened Porch Installation Moisture ResistanceClearance to Combustibles MantelsFraming and Finishing FinishingGas Specification Valve AccessGas Inlet & Manifold Pressures High ElevationsGas Line Installation Parts identificationRemote Wall Switch Remote switch wiringLog Installation Operating InstructionsFirst Firing Flame Adjustment Flame CharacteristicsNova SIT Pilot Installation Instructions Installed. Installation InstructionsOptional Weather Enclosure Optional Stainless Steel HoodLighting and Operating Instructions To Turn Off Gas to HeaterTroubleshooting StartMaintenance CleaningCleaning the Standing Pilot Control System Burner and Burner CompartmentODGR400, ODGR500 DescriptionODGR400, ODGR500 Accessories Accessory Description Model NumberLimited Warranty Mhsc