Monessen Hearth ODGR400, ODGR500 Lighting and Operating Instructions, To Turn Off Gas to Heater

Page 13

ODGR Series Outdoor Gas Fireplace

Lighting and Operating Instructions

FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING:If you do not follow these instructions exactly, a fire or explosion

may result causing property damage, personal injury or loss of life.

A. This heater has a pilot which must be lit manu-

ally. When lighting the pilot follow these instructions exactly.

B.BEFORE LIGHTING smell all around the heater area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any fireplace

Do not touch any electric switch

Do not use any phone in your building

Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.

If you cannot reach your gas supplier, call the Fire Department

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, do not try to repair it, call a qualified service technician. Applying force or any attempted repair may result in a fire or explo- sion.

D.Do not use this fireplace if any part has been under water. Immediately call a qualified service technician to inspect the heater and to replace any part of the control system and any gas control which has been under water.

Lighting Instructions

1.STOP! Read the safety information above.

2.Turn off all electrical power to the fireplace.

3.For MN/MP/TN/TP appliances ONLY, go on to Step 4. For RN/RP appliances turn the On/Off switch to “OFF” position or set thermostat to lowest level.

4.Open control access panel.

5.Push in gas control knob slightly and turn

clockwise to "OFF".

 

 

 

 

PILOT

PILOT

OFF

 

 

 

 

 

t

 

1

 

 

 

 

 

F

 

 

 

lo

 

 

ON

ON

 

P

 

 

 

F

 

 

F

 

i

 

2

 

 

 

 

O

 

O

 

 

 

F

 

 

 

 

 

 

5

 

3

 

FFO

 

 

4

 

 

 

 

 

 

 

 

 

 

Euro SIT

SIT NOVA

Honeywell

6.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow "B" in the safety information above. If you do not smell gas, go to the next step.

7.Remove glass door before lighting pilot. (See Glass Frame Removal section).

8.Visibly locate pilot by the main burner.

9.Turn knob on gas control counterclockwise

to "PILOT".

10.Push the control knob all the way in and hold. Immediately light the pilot by repeatedly depress- ing the piezo spark ignitor until a flame appears. Continue to hold the control knob in for about one

(1) minute after the pilot is lit. Release knob and it will pop back up. Pilot should remain lit. If it goes out, repeat steps 5 through 8.

• If knob does not pop up when released, stop

3/8" - 1/2"

and immediately call your service technician or gas supplier.

If after several tries, the pilot will not stay lit, turn the gas control knob to "OFF" and call your service technician or gas supplier.

11.Replace glass door.

12.Turn gas control knob to “ON” position.

13.For RN/RP appliances turn the On/Off switch to “ON” position or set thermostat to desired setting.

14.Turn on all electrical power to the fireplace.

To Turn Off Gas to Heater

1.Turn the On/Off switch to "Off" position or set the thermostat to lowest setting.

2.Turn off all electric power to the fireplace if service is to be performed.

3.Open control access panel.

4.Push in gas control knob slightly and turn

clockwise to "OFF". Do not force.

5.Close control access panel.

92D0001

13

Image 13
Contents Outdoor Gas Fireplace Models ODGR400, ODGR500 Table of Contents Enclosures for LP-Gas Supply Systems General InformationDescription Fireplace Dimensions Moisture Resistance Screened Porch InstallationClearance to Combustibles MantelsFinishing Framing and FinishingValve Access Gas SpecificationGas Inlet & Manifold Pressures High ElevationsParts identification Gas Line InstallationRemote switch wiring Remote Wall SwitchOperating Instructions Log InstallationFirst Firing Flame Characteristics Flame AdjustmentNova SIT Pilot Installed. Installation Instructions Installation InstructionsOptional Weather Enclosure Optional Stainless Steel HoodTo Turn Off Gas to Heater Lighting and Operating InstructionsStart TroubleshootingCleaning MaintenanceCleaning the Standing Pilot Control System Burner and Burner CompartmentDescription ODGR400, ODGR500ODGR400, ODGR500 Accessory Description Model Number AccessoriesLimited Warranty Mhsc