ODGR Series Outdoor Gas Fireplace
Troubleshooting
Nova SIT 820 Standing Pilot
START
Gas Supply On
YES
Pilot Lights with
Piezo Ignitor
YES
Pilot Stays Lit
YES
Pilot Lights Main
Burner
YES
|
|
|
|
| CHECK |
NO |
|
|
| Supply Line Hooked up | |
|
| ||||
|
|
|
|
| Shutoff Valve Open |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Lockout has engaged. Wait 60 |
|
|
|
|
| seconds and try again. |
|
|
|
|
| Piezo not tight enough for good |
|
|
|
|
| ground. |
NO |
|
|
|
| For spark at electrode while |
|
| depressing Piezo (Red Button) | |||
|
|
|
|
| |
|
|
|
|
| 1/8" gap to pilot hood needed. |
|
|
|
|
| All wiring connections |
|
|
|
|
| Replace Piezo Ignitor |
|
|
|
|
| Thermodisk |
|
|
|
|
| For Air in the lines |
|
|
|
|
| Thermopile needs a minimum |
|
|
|
|
| 325mV. Adjust pilot flame height. |
|
|
|
|
| All wiring connections |
NO |
|
| Replace Thermopile | ||
| |||||
|
|
|
|
| Thermocouple needs a minimum |
|
|
|
|
| of 14mV. |
|
|
|
|
| Defective valve. Turn to pilot, |
|
|
|
|
| meter should read greater than |
|
|
|
|
| 100mV. |
|
|
|
|
| Thermodisk |
Wall switch is not turned on. Watch for grounded wires!
NO Thermopile needs a minimum 325mV
Plugged burner orifice Doors not fully open (Fig. 10)
System OK
FP396
14 | 92D0001 |