Gas Specification
|
|
| Max. | Min. |
Model | Fuel | Gas Control | Input | Input |
ODGR400NV | Nat. | Millivolt Hi/Lo | 60,000 | 42,600 |
ODGR400PV | Prop. | Millivolt Hi/Lo | 60,000 | 44,000 |
ODGR500NV | Nat. | Millivolt Hi/Lo | 60,000 | 42,600 |
ODGR500PV | Prop. | Millivolt Hi/Lo | 60,000 | 44,000 |
Gas Inlet & Manifold Pressures
|
|
|
| Natural | LP |
Minimum Inlet Pressure | 5.5” w.c. | 11.0” w.c. |
Maximum Inlet Pressure | 14.0” w.c. | 14.0” w.c. |
Manifold Pressure | 3.5”w.c. | 10.0” w.c. |
ODGR400 / ODGR500
Certified to
CSA
High Elevations
Input ratings are shown in BTU per hour and are certified without deration from elevations up to 4,500 feet (1,370 m) above sea level.
Nuisance outages may occur at altitudes above 4,500 feet (1,370 m) if dirt, dust, lint and/or cob- webs are allowed to accumulate on burner and/or ODS pilot. Monthly inspection and cleaning is rec- ommended for altitudes above 4,500 feet (1,370 m)
For elevations above 4,500 feet (1,370 m), instal- lations must be in accordance with the current ANSI Z223.1/NFPA 54 and/or local codes having jurisdiction.
Valve Access
Valve access can be accomplished in one of two ways:
1.Remove the front panel just below the front of the hearth pan. This is accomplished by lifting on the panel. To replace the valve access panel line up the two pins with the holes in the surround bottom and push the panel over the front of the hearth pan. (Fig. 5)
2.Lift the brick with the logo on it. (Fig. 6)
ODGR Series Outdoor Gas Fireplace
| FP1414 |
Fig. 5 | Valve access. |
| Logo Brick |
| FP1415 |
Fig. 6 | Lift brick with logo on it to access valve. |
NOTE: When installation is on a hard, flat surface (such as concrete), the surface must be sloped 1/4" per foot away from any structure.
Blocking
1/2” (13 mm) |
|
Hard, Flat Surface |
|
(i.e. concrete) | FP1642a |
Fig. 7 Exterior chase installation.