Desa EVDDVF36PN, EVDDVF36STN Horizontal Termination Configurations, Rise per 12 of horizontal run

Page 10

® DIRECT-VENT GAS FIREPLACE

EVDDVF36PN and EVDDVF36STN

VENTING INSTALLATION

Continued

Horizontal Termination

Configurations

Figures 21 through 23 show different con- figurations for venting with horizontal ter- mination. Each figure includes a chart with vertical minimum/maximum and horizon- tal maximum dimensions which must be met. All connections must be sealed with high temperature silicone sealant as speci- fied in the second warning statement on page 7. All horizontal terminations require

Horizontal Venting

Vertical (V)

Horizontal (H)

49.5" min.

15" max.

(45° elbow, 1' vertical pipe, 90° elbow)

61.5" min.

34" max.

73.5" min.

58" max.

85.5" min.

10' max.

102.5" min.

20' max.

UP

45° Starter

Elbow

Required

Note: The 30° Starter Elbow Must Be Discarded and Replaced with a 45° Starter Elbow.

1/4" rise per 12" of horizontal run.

Figure 21 - Horizontal Termination Configuration for Rigid Venting Using One 90° Elbow

Horizontal Venting

See information in Figure 21 for

Vertical(V) and UP Horizontal(H) maxi-

mums and minimums. The same amounts apply for flexible venting.

FGFVK Vent Kit Shown

Figure 22 - Horizontal Termination Using Flexible Venting

10

106573

Image 10
Contents Check Local Codes Prior to Installation What to do if YOU Smell GASGlossary Terms Horizontal termination above ground level clearancesSelecting Location IntroductionBefore YOU Begin Mantel Clearances PRE-INSTALLATION PreparationClearances FramingGeneral Venting Location of Vent TerminationGeneral Venting Installation Planning Venting InstallationInstallation Precautions Installing Vent System in a ChaseInstallation for Horizontal Termination Snorkel TerminationVent Pipe Connections Horizontal Termination Configurations Rise per 12 of horizontal runVenting with Two 90 Elbows Cathedral Ceiling Installation Installation for Vertical TerminationFlat Ceiling Installation Connect a section of pipe and extend up through the holeVertical Termination Configurations Vertical Horizontal H 1 + Min Max 20 maxVertical Venting Vanguard Rigid Venting High Altitude InstallationParts Lists for Venting Kits and Components Vanguard Flexible VentingBlower Speed Control Installation Installing Optional Wall Mount Switch GWMS2Optional Blower Assembly Installation Blower Speed Control OperationOptional Remote Control Installation Model WRC GAS Line HOOK-UPInstalling LOG SET GAS Supply TestingElectrode assembly is factory preset for Burner Flame AdjustmentElectrode Assembly Adjustment Decorative FacingOperating Guidelines and Maintenance Instructions Burner RemovalLighting Instructions For Your Safety Read Before LightingOperating Fireplace To Turn OFF GAS To ApplianceReplacement Parts Service HintsTechnical Service Wiring DiagramTroubleshooting Burner is lit Delayed ignition burner Manifold pressure is too lowCompany Pane/LP gas companyFrom entering the unit. The maximum Fireplace produces unwanted odorsLocate and correct all leaks Is 1/4 for any horizontal runAccessories Replacement Parts GAS Control Valve High Voltage CableRefractory Pieces Warranty Information

EVDDVF36PN, EVDDVF36STN specifications

Desa EVDDVF36STN and EVDDVF36PN are innovative and versatile electric heating solutions designed for modern indoor environments. These models stand out in the realm of electric heaters due to their advanced technologies, user-friendly features, and energy-efficient characteristics.

One of the main features of Desa EVDDVF36STN and EVDDVF36PN is their dual fuel capability, allowing users to harness the benefits of both electric and gas heating systems. This versatility ensures that users can maintain optimal comfort levels while minimizing energy costs. The models are equipped with a powerful heating element that can efficiently manage large spaces, making them ideal for homes, workshops, or commercial applications.

In terms of technology, both the EVDDVF36STN and EVDDVF36PN are engineered with a high-efficiency heating system that utilizes radiant heat to warm rooms quickly. This technology reduces the time required to reach desired temperatures, ensuring prompt comfort for users. Additionally, the heaters incorporate digital control systems that allow for precise temperature adjustments, enabling users to tailor their heating experience to meet specific preferences.

Another significant characteristic of these models is their sleek and modern design, which blends seamlessly into various interior styles. The cabinets are constructed from durable materials, ensuring longevity and resilience against wear and tear. Both models come with a variety of finishes and colors, allowing users to choose an aesthetic that complements their space.

The Desa EVDDVF36STN and EVDDVF36PN are also equipped with safety features that prioritize user well-being. These include automatic shut-off sensors that activate in case of overheating or if the unit tips over, providing peace of mind to users.

Moreover, these electric heaters are designed with energy efficiency in mind. They have a lower carbon footprint compared to traditional heating systems, contributing positively to environmental conservation efforts. Their efficient operation not only reduces energy consumption but also translates to lower utility bills, making them an economical choice for consumers.

In conclusion, the Desa EVDDVF36STN and EVDDVF36PN electric heaters embody the perfect combination of functionality, technology, safety, and style. Their dual fuel capability, rapid heating technology, and energy efficiency make them an outstanding option for anyone looking to enhance their indoor comfort while being mindful of their environmental impact.