INSTALLATION FOR HORIZONTAL TERMINATION

1.Determine the route your horizontal venting will take. Note: The location of the horizontal vent termination on the exterior wall must meet all local and national building codes and must not be easily blocked or obstructed.

WARNING: Do not recess vent terminal into a wall or siding.

Snorkel terminations are available for terminations requiring a vertical rise on the exterior of the building (see Figures 14 and 15). Snorkel kit SVK is also available (see page 15). Follow the same installation procedures used for standard horizontal terminations. If installing the snorkel termination below grade (base- ment applications), you must provide proper drainage to prevent water from entering the snorkel termination (see Figure 15). Do not back fill around the snorkel termination.

2.Rigid vent pipes and fittings have spe- cial twist-lock connections. Assemble the desired combination of pipe and el- bows to the appliance adaptor with pipe seams oriented towards the wall or floor.

Twist-lock Procedure: The female ends of the pipes and fittings have four locking lugs (indentations). These lugs will slide straight into matching slots on the male ends of adjacent pipes and fit- tings. (All connections must be sealed with high temperature silicone sealant as specified in the second warning state- ment on page 7.) Push the pipe sections together and twist one section clockwise approximately one-quarter turn until the sections are fully locked. See Figure 16, page 9. Note: Horizontal runs of vent must be supported every three feet. Use wall straps for this purpose.

Flexible vent pipe must be installed with spacer springs every 12". See Figure 16, page 9. All connections must be clamped tightly and sealed with high temperature silicone sealant as specified in the sec- ond warning statement on page 7.

12" Minimum

90°

1' Minimum

Snorkel

45°

Figure 14 - Snorkel Termination

90°

Snorkel

 

12" Minimum

1' Minimum

Adequate

Drainage

 

45°

Figure 15 - Snorkel Termination with Drainage Pipe

8

106573

Image 8
Contents Check Local Codes Prior to Installation What to do if YOU Smell GASGlossary Terms Horizontal termination above ground level clearancesBefore YOU Begin IntroductionSelecting Location PRE-INSTALLATION Preparation ClearancesMantel Clearances FramingGeneral Venting Location of Vent TerminationGeneral Venting Venting Installation Installation PrecautionsInstallation Planning Installing Vent System in a ChaseInstallation for Horizontal Termination Snorkel TerminationVent Pipe Connections Horizontal Termination Configurations Rise per 12 of horizontal runVenting with Two 90 Elbows Installation for Vertical Termination Flat Ceiling InstallationCathedral Ceiling Installation Connect a section of pipe and extend up through the holeVertical Termination Configurations Vertical Horizontal H 1 + Min Max 20 maxVertical Venting High Altitude Installation Parts Lists for Venting Kits and ComponentsVanguard Rigid Venting Vanguard Flexible VentingInstalling Optional Wall Mount Switch GWMS2 Optional Blower Assembly InstallationBlower Speed Control Installation Blower Speed Control OperationOptional Remote Control Installation Model WRC GAS Line HOOK-UPInstalling LOG SET GAS Supply TestingBurner Flame Adjustment Electrode Assembly AdjustmentElectrode assembly is factory preset for Decorative FacingOperating Guidelines and Maintenance Instructions Burner RemovalFor Your Safety Read Before Lighting Operating FireplaceLighting Instructions To Turn OFF GAS To ApplianceService Hints Technical ServiceReplacement Parts Wiring DiagramTroubleshooting Delayed ignition burner Manifold pressure is too low CompanyBurner is lit Pane/LP gas companyFireplace produces unwanted odors Locate and correct all leaksFrom entering the unit. The maximum Is 1/4 for any horizontal runAccessories Replacement Parts Refractory Pieces High Voltage CableGAS Control Valve Warranty Information

EVDDVF36PN, EVDDVF36STN specifications

Desa EVDDVF36STN and EVDDVF36PN are innovative and versatile electric heating solutions designed for modern indoor environments. These models stand out in the realm of electric heaters due to their advanced technologies, user-friendly features, and energy-efficient characteristics.

One of the main features of Desa EVDDVF36STN and EVDDVF36PN is their dual fuel capability, allowing users to harness the benefits of both electric and gas heating systems. This versatility ensures that users can maintain optimal comfort levels while minimizing energy costs. The models are equipped with a powerful heating element that can efficiently manage large spaces, making them ideal for homes, workshops, or commercial applications.

In terms of technology, both the EVDDVF36STN and EVDDVF36PN are engineered with a high-efficiency heating system that utilizes radiant heat to warm rooms quickly. This technology reduces the time required to reach desired temperatures, ensuring prompt comfort for users. Additionally, the heaters incorporate digital control systems that allow for precise temperature adjustments, enabling users to tailor their heating experience to meet specific preferences.

Another significant characteristic of these models is their sleek and modern design, which blends seamlessly into various interior styles. The cabinets are constructed from durable materials, ensuring longevity and resilience against wear and tear. Both models come with a variety of finishes and colors, allowing users to choose an aesthetic that complements their space.

The Desa EVDDVF36STN and EVDDVF36PN are also equipped with safety features that prioritize user well-being. These include automatic shut-off sensors that activate in case of overheating or if the unit tips over, providing peace of mind to users.

Moreover, these electric heaters are designed with energy efficiency in mind. They have a lower carbon footprint compared to traditional heating systems, contributing positively to environmental conservation efforts. Their efficient operation not only reduces energy consumption but also translates to lower utility bills, making them an economical choice for consumers.

In conclusion, the Desa EVDDVF36STN and EVDDVF36PN electric heaters embody the perfect combination of functionality, technology, safety, and style. Their dual fuel capability, rapid heating technology, and energy efficiency make them an outstanding option for anyone looking to enhance their indoor comfort while being mindful of their environmental impact.