Desa EVDDVF36PN Installing Optional Wall Mount Switch GWMS2, Blower Speed Control Installation

Page 16

® DIRECT-VENT GAS FIREPLACE

EVDDVF36PN and EVDDVF36STN

INSTALLATION

INSTALLING OPTIONAL WALL MOUNT SWITCH GWMS2

NOTICE: The GWMS2 includes 25' of wire for installation. Your fireplace includes 15' of wire for accessory installation. Choose the length that best fits your needs when installing this accessory.

Peninsula or See-Thru Fireplace Installed

Inside

Wall

Blower

Assembly

For Optional

Fan Kit

Flue

Exit

From Blower

Assembly

The installation of a wall switch allows you to activate the gas control valve and turn the fireplace on and off. The wall switch is to be connected to the incoming 120 volt regular household wiring that supplies elec- tricity to the fireplace. Refer to wiring diagram on page 22.

WARNING: Disconnect all electrical power to the fireplace. Be careful of burrs and sharp edges.

OPTIONAL BLOWER ASSEMBLY INSTALLATION

Before blower assembly can be operated, it must be properly connected to a standard 120 VAC power source. Refer to Wiring Diagram on page 22.

1.To remove lower louver, pull both top spring latches toward the center of the appliance at the same time until they are disengaged from the locating holes. Repeat for bottom spring latches and pull louver outward.

2.Place blower assembly so it rests flush against the inside wall on the flue exit side of the firebox (see Figure 32). There are four magnets on the bottom of the blower assembly that will keep the blower in place on firebox bottom. Note: If the blower kit is not installed flush against the inside side wall of the fireplace, the circulating air from the blower system will not flow properly.

Blower Center to

Firebox Bottom

Center Along Inside

Wall by Flue Exit

Figure 32 - Blower Assembly Placement

BLOWER SPEED CONTROL INSTALLATION

1.Place speed control switch assembly on the bottom of the inside of the firebox (see Figure 33). The assembly is equipped with magnets on the left and right to properly anchor it to the firebox.

2.Plug blower with speed control assem- bly into a power source. Keep hands clear of fan when running. Note: An outlet box with two receptacles has been supplied for your convenience, located on the lower left side of the appliance (see Figure 34). An optional remote control may be installed at any time.

CAUTION: Due to high tem- peratures, make sure no wires are touching the bottom of the firebox.

Glass

Spring

Latch

Speed Control

Magnet

Figure 33 - Blower Speed Control Location

Figure 34 - Connecting Blower Accessory to Power Supply

 

 

Wire Connectors

 

 

3 Places

BLOWER

BLK (16 ga.)

BLOWER

 

BLK (16 ga.)

SPEED

ASSEMBLY

 

 

CONTROL

Figure 35 - Wiring Diagram for Blower Assembly

BLOWER SPEED CONTROL OPERATION

1.To operate blower, turn the blower speed control knob clockwise to the “on” po- sition (see Figure 36). This will be the highest blower speed. Continue turning knob clockwise to reduce blower speed. Turn knob only within the specified range (1/4 revolution, see Figure 36).

2.To turn blower off, turn blower speed control knob counter-clockwise until it clicks into the “off” position. You must turn until knob clicks for the unit to be completely off.

High Speed

ON/OFF

1/4 Revolution

Low

Speed

Magnets

Figure 36 - Blower Speed Control

16

106573

Image 16
Contents Check Local Codes Prior to Installation What to do if YOU Smell GASGlossary Terms Horizontal termination above ground level clearancesSelecting Location IntroductionBefore YOU Begin PRE-INSTALLATION Preparation ClearancesMantel Clearances FramingGeneral Venting Location of Vent TerminationGeneral Venting Venting Installation Installation PrecautionsInstallation Planning Installing Vent System in a ChaseInstallation for Horizontal Termination Snorkel TerminationVent Pipe Connections Horizontal Termination Configurations Rise per 12 of horizontal runVenting with Two 90 Elbows Installation for Vertical Termination Flat Ceiling InstallationCathedral Ceiling Installation Connect a section of pipe and extend up through the holeVertical Termination Configurations Vertical Horizontal H 1 + Min Max 20 maxVertical Venting High Altitude Installation Parts Lists for Venting Kits and ComponentsVanguard Rigid Venting Vanguard Flexible VentingInstalling Optional Wall Mount Switch GWMS2 Optional Blower Assembly InstallationBlower Speed Control Installation Blower Speed Control OperationOptional Remote Control Installation Model WRC GAS Line HOOK-UPInstalling LOG SET GAS Supply TestingBurner Flame Adjustment Electrode Assembly AdjustmentElectrode assembly is factory preset for Decorative FacingOperating Guidelines and Maintenance Instructions Burner RemovalFor Your Safety Read Before Lighting Operating FireplaceLighting Instructions To Turn OFF GAS To ApplianceService Hints Technical ServiceReplacement Parts Wiring DiagramTroubleshooting Delayed ignition burner Manifold pressure is too low CompanyBurner is lit Pane/LP gas companyFireplace produces unwanted odors Locate and correct all leaksFrom entering the unit. The maximum Is 1/4 for any horizontal runAccessories Replacement Parts GAS Control Valve High Voltage CableRefractory Pieces Warranty Information

EVDDVF36PN, EVDDVF36STN specifications

Desa EVDDVF36STN and EVDDVF36PN are innovative and versatile electric heating solutions designed for modern indoor environments. These models stand out in the realm of electric heaters due to their advanced technologies, user-friendly features, and energy-efficient characteristics.

One of the main features of Desa EVDDVF36STN and EVDDVF36PN is their dual fuel capability, allowing users to harness the benefits of both electric and gas heating systems. This versatility ensures that users can maintain optimal comfort levels while minimizing energy costs. The models are equipped with a powerful heating element that can efficiently manage large spaces, making them ideal for homes, workshops, or commercial applications.

In terms of technology, both the EVDDVF36STN and EVDDVF36PN are engineered with a high-efficiency heating system that utilizes radiant heat to warm rooms quickly. This technology reduces the time required to reach desired temperatures, ensuring prompt comfort for users. Additionally, the heaters incorporate digital control systems that allow for precise temperature adjustments, enabling users to tailor their heating experience to meet specific preferences.

Another significant characteristic of these models is their sleek and modern design, which blends seamlessly into various interior styles. The cabinets are constructed from durable materials, ensuring longevity and resilience against wear and tear. Both models come with a variety of finishes and colors, allowing users to choose an aesthetic that complements their space.

The Desa EVDDVF36STN and EVDDVF36PN are also equipped with safety features that prioritize user well-being. These include automatic shut-off sensors that activate in case of overheating or if the unit tips over, providing peace of mind to users.

Moreover, these electric heaters are designed with energy efficiency in mind. They have a lower carbon footprint compared to traditional heating systems, contributing positively to environmental conservation efforts. Their efficient operation not only reduces energy consumption but also translates to lower utility bills, making them an economical choice for consumers.

In conclusion, the Desa EVDDVF36STN and EVDDVF36PN electric heaters embody the perfect combination of functionality, technology, safety, and style. Their dual fuel capability, rapid heating technology, and energy efficiency make them an outstanding option for anyone looking to enhance their indoor comfort while being mindful of their environmental impact.